IS200 Electro-Hydraulic Actuator Positioner 

 

 

Orange Instruments Limited. 

Drwg. No.: 1357-007     Issue : K     Date : 07/10/2013          Page : 

2 of 9 

Iss c - Certificate number added.   Iss D - Ta changed to -20 to +60    
Iss E - Details of fail modes, timers and retrans. O/P added.   Retrans. Signal barrier changed to KFD0-CC-Ex1  
Iss F 

– Details of change in Max/min on & off times + addition of 10R in line with pos o/p –ve 

Iss G 

– Stepping times range change to allow finer adjustment 15/11/2007 

Iss H 

– CE Cert. of Conformity details added, Ta to –40degC, 60079:0,26 mods 25/06/2008 

Iss J 

– Harmonised standards in C of C modified to meet current status 04/08/2008 

Iss K -  Markings changed to meet EN 60079-0:2012 02/10/2103 
ATEX Certified Equipment - Change Authority ATEX Manager ONLY 

Manufacturer and Approvals Details 

The IS200 is manufactured and maintained solely by: 
 
Orange Instruments Limited 

 

Telephone  

+44 (0)1604 790490 

Lower Farm Road 

 

 

Fax  

 

+44 (0)1604 790690 

Moulton Park 

 

 

 

email 

 

 

sales@orangeinstruments,co.uk

 

Northampton 
NN3 6XF 
United Kingdom 
 
The IS200 has the following specific approvals 
 
Name and Type  

 

 

 

ACTUATOR POSITIONER TYPE IS200 

Certificate Number 

 

 

 

Baseefa 03ATEX0686X 

Specific Marking of Explosion Protection  

Ex ia IIC T4 Ga(-40ºC 

Ta 

 +60ºC)

 

ATEX Directive Marking  

 

 



II 1 G  

Notified body 

 

 

 

 

Baseefa 1180 

 
 

 

Features                                                                     
 

  Simple two-step calibration 

 

  4-20mA current command signals and current or potentiometer feedback signal.  

 

  Actual position calibrated output 

 

  MANUAL mode  

 

  Stepping mode with adjustable ON and OFF times 

 

  Selectable solenoid drive for failsafe operation 

 

  Selectable default operation on command signal/feedback signal break 

 

  ESD solenoid output / Fault output relaxed by control signal breaks

 

 

      EC Declaration of Conformity

  

Manufacturer 

Orange Instruments Limited 
Lower Farm Road 
Moulton Park 
Northampton NN3 6XF 
United Kingdom 

 

Equipment description 

Actuator Positioner Type IS200  



II 1 G

 

Ex ia IIC T4 Ga 

       (-40

C

Ta

+60

C)

 

 

Notified body 

Baseefa 1180 
Rockhead Business Park  
Staden Lane, Buxton 
Derbyshire SK17 9RZ 
United Kingdom 

 

Harmonised Standards

 

EN 60079-0:2012 
EN 60079-11:2012 
 

Other Standards

 

Signed       

 

Anthony G. McCormick 
ATEX Manager 
Orange Instruments 

Summary of Contents for IS200

Page 1: ...IS200 Intrinsically Safe Actuator Positioner Operation Installation and Maintenance Manual Operation Installation and Maintenance Manual ORM0006 IS200 O M Rev 0...

Page 2: ...co uk Northampton NN3 6XF United Kingdom The IS200 has the following specific approvals Name and Type ACTUATOR POSITIONER TYPE IS200 Certificate Number Baseefa 03ATEX0686X Specific Marking of Explosi...

Page 3: ...t panel of the enclosure Wiring To comply with the IS Certification the IS200 must be wired as shown in the circuit on Page 7 Wiring should be completed by suitably trained personnel taking into accou...

Page 4: ...s required the ON and OFF timers for the open and close solenoids have to be set This operation is best performed when the actuator hydraulics are isolated but the settings can be trimmed during norma...

Page 5: ...sh twice briefly every second 6 Use the INCREASE and DECREASE buttons to set the actuator to the required position for the maximum 20mA command signal As before this can be any position within the mec...

Page 6: ...standards in C of C modified to meet current status 04 08 2008 Iss K Markings changed to meet EN 60079 0 2012 02 10 2103 ATEX Certified Equipment Change Authority ATEX Manager ONLY IS200 dimensions a...

Page 7: ...y Safe barriers before connection to the IS200 See circuits on Page 7 COMMAND SIGNAL INPUT 4 20mA nominal 240R input impedance ANALOGUE POSITION OUTPUT SIGNAL 0 4 9V can be calibrated anywhere in this...

Page 8: ...2 24V dc 7 8 16 15 16V 1 2 24V dc 7 8 3 4 16V 1 2 24V dc 7 8 8 9 4 20mA 1 5 6 4 20mA Command MK35 Li Ex0 2 24V dc 7 8 20 21 0 4 9V 1 9 8 KFD0 CC Ex1 2 18 19 6 7 2 1 13 14 or Fault O P ESD Soln Instume...

Page 9: ...16V Always at supply potential 2 Increase Solenoid ve output 16V Set to 0V to energise solenoid 3 Increase Solenoid Supply ve 16V Must be an isolated IS supply 4 Increase Solenoid Supply 0V 0V 5 No c...