Installation, Operation and Maintenance Manual
MAN 608 Rev. 5
December 2020
Troubleshooting
37
Section 6: Troubleshooting
Section 6: Troubleshooting
6.1
Failure or Breakdown Research
Table 13.
Event
Possible cause
Remedy
Actuator does not work
Lack of power supply
Restore it
Lack of hydraulic supply
Open line interception valve
Failure of the spring
Call Biffi Italia s.r.l. Customer Service
Blocked valve
Repair or replace
Wrong position of the distributor of the
manual hydraulic group
Restore correct position
Failure of the control group
Call Biffi Italia s.r.l. Customer Service
Unexpected intervention of torque
limit-device
Call Biffi Italia s.r.l. Customer Service
Low supply pressure
Restore (Section 1.4)
Actuator too slow
Low supply pressure
Restore (Section 1.4)
Wrong calibration of flow regulator valves
Restore (Section 3.6)
Bad functioning of quick exhaust valve
Wear of the valve
Call Biffi Italia s.r.l. Customer Service
Actuator too fast
High supply pressure
Restore (Section 1.4)
Bad functioning of booster/quick
exhaust valve
Call Biffi Italia s.r.l. Customer Service
Wrong calibration of flow regulator valves
Restore (Section 3.6)
Leakages on hydraulic
or pneumatic circuits
Deterioration and/or damage to gaskets
Call Biffi Italia s.r.l. Customer Service
Incorrect position of
the valve
Wrong adjustment of mechanical stops
Restore (Section 3.4)
Wrong warning of micro-switches
Restore (Section 3.5)
Hydraulic manual
pump does not work
Handle positioned on remote control
Position the handle on the indication
of the operation to make
Leakages on the check valve of the hydraulic
control group
Call Biffi Italia s.r.l. Customer Service