Pos.
Qty.
Denomination
Material
Type or Drawing
8
1
OR+2BK (included in cartridge pos. 2)
MFQ-70Sh+PTFE
OR2-013+2BK
7
1
Handwheel
11S (2011)
29.102.378
6
4
Screw
A4-70
VTCEI M5x45 UNI 5931
5
2
O-ring
MFQ-70Sh
OR 5-612
4
1
Screw
A4-70
M5x5 UNI 5923
3
1
O-ring (included in cartridge pos. 2)
MFQ-70Sh
OR 2-116
2
1
Cartridge
AISI 316
FT 2267/2- 14-FQSV
1
1
Body
AISI 316
49.144.031
December 2020
Installation, Operation and Maintenance Manual
MAN 608 Rev. 5
Operation and Use
1
7
2
3
8
4
5
6
26
Section 3: Operation and Use
Technical features:
Max. adjusted flow (l/min.)
10
Max. working pressure (bar)
250
Fluid viscosity range (cSt)
5 - 750
Fluid temperatuure range (°C)
-45 +60
Mass (kg)
0.70
Hydraulic fluid: mineral oils
Recommended filtration: 19/15 ISO 4466 (25 µ obsolutes)
Seals in MFQ (Fuoro-silicone)
Figure 22
Adjustment of operating time by flow regulator valve
OUT
IN
Torque 30 Nm
Torque 5 Nm
3.6
Calibration of the Operation Time (If Required)
The calibration of the operation time is made by Biffi Italia s.r.l, according to customer
requirements and to technical data-sheet included in technical documentation. If
necessary it’s possible to modify or reset the operating time through two flow regulation
valves (optional) placed on inlets of hydraulic cylinder (see Figure 22 and the applicable
operating diagram).
To carry out the adjustment, operate the handwheel (turn clockwise the handwheel to
increase the operating time or turn the handwheel counterclockwise to decrease the
operation time).
Table 9.