HLA
– Double acting- hydraulic linear actuator
Use and maintenance manual
© Copyright by BIFFI Italia. All right reserved.
Pag. 34
Contents may change without notice
6
Troubleshooting
6.1
FAILURE OR BREAKDOWN RESEARCH
Event
Possible cause
Remedy
Actuator does not
work
Lack of hydraulic
supply
Open line stop valve
Blocked valve
Repair or replace
Wrong position of the
distributor of the
hydraulic manual
override
Restore correct
position
Failure of the control
system
Call BIFFI Italia S.r.l.
Customer Service
Clogged filter
Clean or replace the
cartridge.
Actuator too slow
Low supply pressure
Restore (Sect. 1.4)
Wrong calibration of
flow regulator valves
Restore (Sect. 3.6)
Wear of the valve
Replace
Actuator too fast
High supply pressure
Restore (Sect. 1.4)
Wrong calibration of
flow regulator valves
Restore (Sect. 3.6)
Leakages on
hydraulic or
pneumatic circuits
Deterioration and/or
damage to gaskets
Call BIFFI Italia S.r.l.
Customer Service.
Incorrect position of
the valve
Wrong adjustment of
mechanical stops
Restore (Sect. 3.4)
Wrong warning of
microswitches
Restore (Sect. 3.5)
Hydraulic manual
pump does not work
handle positioned on
remote control
Position the handle on
the indication of the
operation to make
Leakages on the check
valve of the hydraulic
control group
Call BIFFI Italia S.r.l.
Customer Service
Incorrect position of
the valve
Wrong adjustment of
mechanical stops
Reset (Par. 3.4)
Wrong warning of
micro-switches
Reset (Par. 3.5)