5. Instructions For Use Cont.
Adjustment:
• In order to achieve optimal settings for
economy and comfort, we recommend
adjusting the operating temperature of
the central heating water according to the
outside temperature, positioning the knob
as in figure 5.7.
• Your installer may have installed addi-
tional energy saving equipment and will
be able to recommend the most suitable
adjustment for your system.
• The LCD indicates if the set temperature
has been reached.
Request for heating power.
If the boiler requests heating power, you
can see the sequence on the LCD display
in Figure 5.8.
Figure 5.7
From 41 to 59°F Between 23 and 41°F
Lower than 23°F
Figure 5.8
5.6 Extinguishing Instructions:
• To turn the boiler off set the function selec-
tor 7 to the position shown in the Figure
5.9.
• Signal given by the LCD display Figure
5.10.
• Turn off electric power to the appliance
at the circuit panel of boiler serviceman’s
switch.
Figure 5.9
8
7
Figure 5.10