- 81 -
MAINTENANCE
MAINTENANCE
ward), until the LCD display shows the
code
P06
, indicating entry into “parameter
P06” (Fig. 10.21).
Fig. 10.21
bar
RESET
•
Press the 16 key to show the value of
parameter P06 on the LCD display (Fig.
10.22).
Fig. 10.22
bar
RESET
•
Press the 16 key and the LCD display
shows the number
01
, indicating activa-
tion of the “chimney sweep function” at
minimum output (Fig. 10.23).
•
Press the 12 key (Fig. 10.19) to confirm
the value entered and activate the func-
tion.
Fig. 10.23
bar
RESET
Flue sweep function at maximum output
in domestic hot water mode
•
Press the 16 key and the LCD display
shows the number
01
, indicating activa-
tion of the “chimney sweep function” at
minimum output in domestic hot water
mode.
•
Press the 12 key (Fig. 10.19) to confirm
the value entered and activate the func-
tion (Fig. 10.24).
Fig. 10.24
bar
RESET
Flue sweep function at maximum output
in heating mode
•
Press the 16 key and the LCD display
shows the number
03
, indicating activa-
tion of the “chimney sweep function” at
maximum output in heating mode.
•
Press the 12 key (Fig. 10.19) to confirm
the value entered and activate the func-
tion (Fig. 10.25).
Fig. 10.25
bar
RESET
Exiting the chimney sweep function
•
To exit the chimney sweep, reset the value
of parameter
P06
to
00
or wait 15 minutes
with the boiler switched off (
OFF
).
•
Switch off the boiler by pressing button 17
(Fig. 10.19) until the letters
OFF
appear
on the LCD display (Fig. 10.26).
Fig. 10.26
bar
RESET
Summary of Contents for BASICA COND
Page 86: ... 86 NOTES ...
Page 87: ......