- 33 -
INST
ALLA
TION
TECHNICAL INFORMATION
Gas rate maximum - central heating
Natural G20
m
3
/h
2,91
Propane G31
kg/h
2,14
Gas rate maximum - domestic hot water
Natural G20
m
3
/h
3,39
Propane G31
kg/h
2,49
Gas rate minimum – C.H. - D.H.W.
Natural G20
m
3
/h
0,66
Propane G31
kg/h
0,48
Electrical data
Voltage
V~
230
Frequency
Hz
50
Nominal Power consumption
W
106
Minimum Power consumption
W
14
Stand-by Power consumption
W
3
Protection degree
IPX5D
External fuse rating
A
3
Internal fuse rating
A
N° 2 - 2
AF
Flue design
Boiler type
B23P C13 C33 C43 C53 C63 C83 C93
Ø Coaxial
mm
60/100
Ø Twin split pipes
mm
80/80
Ø Roof
mm
60/100
Ø Roof
mm
80/125
Nominal heat flow rate
(A) (E)
kW
32,0
Exhaust temperature
(E)
°C
83,0
Mass flow rate
(E)
kg/s
0,0142
Flue gas figures
Nominal heat input
(A) (E)
kW
32,0
CO
2
content with gas G20
%
9,1 - 9,7
O
2
content with gas G20
%
4,1
CO content with gas G20
ppm
190,0
Exhaust temperature
(E)
°C
83,0
NOx class
6
Weighted NOx
ppm
19
(E)
Values refer tests with a 1 m flue working at the
nominal heat input
CO
2
contents - central heating
Nominal heat input
(A) (E)
kW
27,5
CO
2
content with gas G20 (range
min - max)
%
9,0 - 9,6
CO
2
content with gas G31 (range
min - max)
%
10,2 -
10,8
Minimum heat input
(A) (E)
kW
6,2
CO
2
content with gas G20 (range
min - max)
%
8,2 - 8,8
CO
2
content with gas G31 (range
min - max)
%
9,4 -
10,0
CO
2
contents - domestic hot water
Nominal heat input
(A) (E)
kW
32,0
CO
2
content with gas G20 (range
min - max)
%
9,1 - 9,7
CO
2
content with gas G31 (range
min - max)
%
10,3 -
10,9
Minimum heat input
(A) (E)
kW
6,2
CO
2
content with gas G20 (range
min - max)
%
8,2 - 8,8
CO
2
content with gas G31 (range
min - max)
%
9,4 -
10,0
Summary of Contents for BASICA COND
Page 86: ... 86 NOTES ...
Page 87: ......