- 70 -
INST
ALLA
TION
ADVANCED COMMISSIONING
8.4 Selecting the reignition fre-
quency
When the boiler functions in normal on/off
heating mode, the minimum time between
two ignitions is set at three minutes (re-igni
-
tion frequency).
This time can be changed by a minimum
of zero to a maximum of eight and a half
minutes.
•
Enter the "programming mode" by
se-
quentially pressing keys 16 - 17 - 18 (Fig.
8.22) for 10 seconds at the same time un
-
til the letters
Pr
that alternate with code
01
are displayed on the LCD display, indi
-
cating that "parameter 01" (Fig. 8.23) has
been activated.
Fig. 8.22
14
15
16
17
18
Fig. 8.23
•
Scroll the various parameters using keys
17 or 18 until the letters
Pr
that alternate
with code
10
are displayed on the LCD
display, indicating that "parameter 10"
(Fig. 8.24) has been activated.
Fig. 8.24
•
Press keys 16 and 18 (Fig. 8.22) at the
same time until the value of parameter
10 (30=180 seconds) is displayed on the
LCD display (Fig. 8.25).
Fig. 8.25
•
It is possible to modify parameter 10 by
00=
0s to
99=
600s using keys 17 or 18
(each increase or reduction by a unit on
the display corresponds to 6 seconds).
•
By pressing key 16 (Fig. 8.22) confirma
-
tion of the inserted value is obtained.
•
Press keys 16 and 17 (Fig. 8.22) at the
same time to exit without changing the
value (return to the parameters list Fig.
8.24).
•
Press sequentially keys, 16 - 17
and then
18 (Fig. 8.22) and hold in for 10 seconds
to exit the "programming mode".
Programming using the REMOTE control
Act on the programming of the REMOTE
control to select a minimum time between