11
VEGA
Fig. 6.3
OK
Fig. 6.4
NO
Fig. 6.5
Fig. 6.6
6.2
Main Power supply connection
The distributor is predisposed to function with mono-phase 230
Volt tension and is protected with 10A fuse.
We suggest to check that:
the tension of net of 230 V doesnt have a difference of more
than ± 6%
The power supply output is able to bear the power load of the
machine.
use a system of diversified protection
position the machine in such a way as to ensure that the plug
remains accessible
The machine must be connected to earth in observance with the
current safety norms.
For this reason, verify the plants earth wire connection to ascertain
that it is efficient and it answers national and European safety
electric standards.
If necessary require the intervention qualified personnel for the
verification of the plant.
The distributor is equipped with a power supply cable of H05VV-
F 3x1,5mm², with SCHUKO plug (Fig.6.4).
The sockets that are not compatible with that of the machine
must be replaced. (Fig.6.5).
The use of extension, adapters and/ or multiple plugs is
forbidden.
Nuova Bianchi S.p.A.
declines all responsibility for damages
product from the non observance of the aforesaid norms.
Should the power cable be found to be damaged, immediately
disconnect from the power socket.
The power supply cables are to be replaced by
skilled personnel.
Make sure that the grills behind and under the radiator are
always free and not obstructed by dust or similar objects in
order to guarantee perfect ventilation for the cooling unit.
It is recommended that the distributor be fixed to the wall
using the two brackets provided. Fix them first to the distributor
(fig.6.3) and then to the wall.
WARNING!
Do not position the device near inflammable
objects, keep a minimum safety distance of 30 cm..
Nuova Bianchi
declines every responsibilty for any damage due
to the non-observance of the rules about machine positioning.
If the machine is installed in an emergency exit corridor, ensure
that when the distributor door is open there is still enough space
to pass.
(Fig.6.1)
.
6.3 Starting up of the unit
The distributor is equipped with safety switch (Fig.6.6) that
disconnects the machine whenever the door is opened ( see electric
schema).
In case of necessity, therefore, open the door or disconnect taking
of the machine from the power supply.