33
5.1.2 Menu ‘Temperature’
Boiler Temp. 1 Slave X Boiler 1 temperature [ 70÷ 110 °C] The
wording Slave X indicates the slave number
linked to the MASTER distributor.
Boiler Temp. 2 Slave X Boiler 2 temperature temperature [ 70÷
110 °C] The wording Slave X indicates the slave
number linked to the MASTER distributor.
Cool Unit temp. Slave X
Cool water temperature [ 0÷ 15 ° C] The
wording Slave X indicates the slave number
linked to the MASTER distributor.
Inner temp. Slave X Inner A temperature [ 5 ÷ 15 °C for the SNACK
model and 1÷ 15 °C for the PAN model, > 15 °C
= Off] Sets the operating temperature of D.A.
The wording Slave X indicates the slave number
linked to the MASTER distributor.
Delta Temp. Slave X Cool temperature hysteresis A [ 1.0 ÷ 5.0 ° C]
It determines the interval with respect to the
programmed temperature to connect and di-
sconnect the compressor. The wording Slave X
indicates the slave number linked to the MASTER
distributor.
Offset temp. Slave X Cool Offset temperature A [ -5÷ 5 ° C] The wor-
ding Slave X indicates the slave number linked
to the MASTER distributor.
Delta Safety Slave X Delta Cool Safety A [5÷ 50 ° C] It is enabled only
in PAN confi guration, it determines the safety
temperature. The wording Slave X indicates the
slave number linked to the MASTER distributor.
T Safety Slave X
Safety T Cool A [ 1÷ 9 hours] Interval expres-
sed in hours within which the selections of the
2 lower cabinets are still available despite the
cell temperature is higher than 7 ° C. (Safety
temperature) for instance after the installation
or the loading of the distributor. The wording
Slave X indicates the slave number linked to the
MASTER distributor.
Defrost after Slave X Defrost frequency Cool A [ 1÷ 12 hours ] Inter-
val expressed in hours in order to defrost the
radiator. The wording Slave X indicates the slave
number linked to the MASTER distributor.
Defrost for Slave X Duration cool defrost A [ 1÷ 30 minutes] Interval
expressed in minutes which determines the du-
ration of the deactivation of the compressor for
the defrosting. The wording Slave X indicates the
slave number linked to the MASTER distributor.
PAN cycle:
The cycle provides for the activation
of the distributor, so that, if the pro-
be detects an internal temperature >- to the
safety one, there is the selection blockage.
Within a limit time of 30 sec, signalled by the
buzzer activation, it is possible to disable the
alarm by entering the code A 98 or B 98 on
the keyboard.
The temperature alarm will be disabled for
the programmed safety time; when such
time expires the safety temperature control
will be enabled. If on, the detected tempe-
rature is < than the safety one (non alarm
condition), such temperature control is
enabled. The reset of such alarm is possible
both in maintenance mode, and deactivating
and activating the machine, by composing
the code A98 or B98 within 30 sec of the
buzzer operation.
If the inner temperature does not reach the
preset value as safety temperature, the se-
lections from 51 to 68 are blocked making
them automatically “NOT AVAILABLE”
5.1.3 Menu ‘Preselections’
All push buttons can be preset
Push button 01…30
Withoth product
Product
[0…9] 0= disabled
Double product 1 [ 0…9]0= disabled. Valid
only for drinks with expresso coffee or soup
coffee. It replaces coffee with selected
soup.
Double product 2 [ 0…9] 0= disabled
Valid only for drinks with expresso coffee
or soup coffee. It replaces coffee with
selected soup.
INC+ / DEC - Sugar
T sugar
[0 …25.5 s]
H2O
[0…25.5 s] or[0…999 cc]
Only for soup drinks
DEC-? Key
01 …30 Choose the DEC-
push button and possible STOP
Stop Management? STOP preset manage-
ment [ On/Off] When the drink is selected,
small slowly scrolling squares are being
displayed. Once the desired quantity has
been selected, the distributor will start to
prepare the drink.
Fixed in line 2? Sugar bar management
always on the second line instead of the rea-
ding Ready [ On/Off] If ON the alarm signal-
lings are not displayed in the second line.
Display management of the preset INC+ /
DEC- Sugar
Line
1
:
Sugar
Line
2
:
Each small square is equivalent to x sec of data
sugar from the following equation:
= (A+B)/8
A
= Q.ty in seconds of sugar in the standard
drink
B
= Q.ty in seconds of sugar in the preselec-
tion + sugar
8
= Maximum number of small squares
Generic preset
Product
[ 0…9] = disabled
T product
[ 0…25.5 s]
H2O
[0…25.5 s] or [ 0…999 cc]
T double product [0…25.5 s]
H2O double
[0…25.5 s] or [0..999 cc] If 0 ++ disabled.
Stop? Management Preset STOP Management [ On/Off] When
the drink is selected small slowing scrolling
small squares are being displayed. Once the
desired H2 0 Volume is selected, the distri-
butor starts to prepare the drink.
Extra Management? Extra product management [ On/Off] If on it
pe and ++, if off – and --. Of course
if Stop Management is Off.
User jug
It manages the push button as JUG PUSH
BUTTON 1..12 through increase of 1. [ On/
Off] If ON the change of menu Doses is not
displayed. The jug will be managed only
on the selections which are enabled for this
process.
Cup
No Cup
No Preselection