Bianchi Industry BVM 351 Use And Maintenance Manual Download Page 21

21

1

2

3

4

5

6

7

8

2. Read- off and w rit ing of t he relat ive m essages. All t he language 

m essages are st ored int o t he hand- held unit . Said dat a w ill be 
m anaged  by  t he  VSPS  w indow s  program   and  by  t he  relat ive 
alt erat ion and am endm ent  program s. The operat ion procedure 
is described in t he VSPS inst ruct ion m anual.

3. Read- off and w rit ing of t he relat ive calibrat ions. All t he calibra-

t ion  records  are  st ored  int o  t he  hand- held  unit .  Said  dat a  w ill 
be m anaged by t he VSPS w indow s program  and by t he relat ive 
alt erat ion and am endm ent  program s. The operat ion procedure 
is  described  in  t he  VSPS  inst ruct ion  m anual.  The  dat a  t hat   is 

managed is as specified under the “Calibration data key ma

-

nagem ent ”  sect ion.

BOI LER EM PTYI N G M AN AGEM EN T

I nput s and out put s involved:

I n pu t s

Ou t pu t s

Group m icro I NPUT2: 8 

Group m ot or OUT3: 6

Pushbut t on 1

Coffee elect ro valve:  OUT3: 2

The procedure is act ivat ed by keeping key 1 pressed in w hile t he 
m achine pow ers on, unt il you hear t he beep. 
Upon  sw it ch- on,  once  t he  T1  int erval  has  gone  by,  t he  group  is 
act ivat ed and t ravels int o t he dispensing posit ion.

The coffee electro valve is thus activated for a fixed time interval 

T2  ( 15  seconds) .  Once  said  t im e  int erval  ha  gone  by,  t he  group 
w ill go back int o rest  posit ion. The VM gives off anot her beep and 
t he display w ill display t he “ Sw it ch off ”  m essage.

TROUBLE SH OOTI N G

●  The group timeout expire (Timing and thresholds menu), the 

“ E61 Group”  syst em - st ored signal is generat ed and t he dispen-
sing cycle is brought  t o an end.

DATA DI SPLAY

I n  ph a se  A

Empty   

fixed message.

Boiler    

fixed message.

I n  ph a se  B

Switch off  

fixed message.

9 .0   M AI N TEN AN CE

9 .1   SOFTW ARE FUN CTI ON  M AN AGEM EN T

KEY FUN CTI ON S

The  m aint enance  m enu  is  accessed  by   keeping  pushbut t on  4 
pressed in for 4 seconds.

The pushbut t ons provided are m eant  for:

Pushbut t on 

1

  

Alarm  reset s

Pushbut t on 

2

  

Scrolling t hrough alarm s and warnings

Pushbut t on 

3

  

Com plet e t est  run

Pushbut t on 

4

  

Group rot at ion

Pushbut t on 

5

  

Cleaning

Pushbut t on 

6

  

Select ion display

Pushbut t on 

7

  

Act ivat e grinder opening for 5 sec

Pushbut t on 

8

  

Exit

When  in  t he  m aint enance  m ode,  t he  follow ing  m essages  com e 
up on display:

Maint enance

 

 

I n t he event  t hat  any alarm s have t ripped off  

 

 

or t here are any warnings, t he relat ive alarm   

 

 

m essage or signal is displayed in line t w o.

ALARM  RESET

Upon pressing t he key all alarm s and warnings are reset , t hen t he 
coffee  group  reset   procedure  is  act ivat ed  ( please  see  t he  group 
rot at ion funct ion) .
The fact ory dat a are rest ored only if t he Eeprom  alarm  is t riggered 
off as w ell.

DATA DI SPLAY
Dur ing  t he  syst em   r eset ,  t he  follow ing  m essage  com es  up  on 
display in line 2:

Reset

ALARM S AN D  W ARN I N GS SCROLL- D OW N

This  funct ion  can  be  im plem ent ed  if  t here  are  alarm   or  signal 
m essages present . I f t here are, pressing t he relat ive scroll- dow n 
key it  is possible t o scroll t hrough t he list  of alarm s and warnings 
present  and displayed in line 2.

COM PLETE TEST RUN

This  funct ion  allow s  t he  operat or   t o  r un  t est   select ions  of  t he 
possible drinks available. During t he t est  run servings, t he preven-
t ive act ion m enu decount ers are m anaged w hilst  t he sales m enu 
count ers w ill not  be increased.
I f  t he  com plet e  t est   run  m ode  is  accessed  and  you  w ish  t o  exit  
w it hout   ent ering  any  t est   select ions,  sim ply  press  t he  STOP  pu-
shbut t on.

Summary of Contents for BVM 351

Page 1: ...BVM 3 5 1 CERT N 9191 BNVN UNI EN ISO 14001 2004 CERT N 9105 BNVD UNI EN ISO 9001 2000 USE AND MAINTENANCE MANUAL...

Page 2: ......

Page 3: ...75 2003 06 Special requirements for commercial dispensers and automatic vending machines EN ISO 11201 EN ISO 3744 Measurement of acoustic noise 2 ELECTROMAGNETI C COMPATI BI LI TY EMC EN 55014 1 Emis...

Page 4: ...ier recycling of the materials forming the equipment Any unauthorized disposal of the product by the user will imply the enforcement of the administrative sanctions as set out in Legislative Decree no...

Page 5: ...of all the necessary machine cleaning operations In the event of machine breakdowns the operator is required to contact the installation and service technicians accordingly I NSTALLATI ON TECHNI CI A...

Page 6: ...s right until the machine is actually stripped and scrapped In case of loss or damage of the present manual it is possible receive a new copy making application to the manufacturer with prior indicati...

Page 7: ...acilities with temperatures not less than 5 C It is pos sible to stack only up to three packages of the same machine on top of one another Avoid placing any other types of heavy packages on top of the...

Page 8: ...aled or maintenance free volumetric pump Water heating is provided via conductive thermal exchange in the boiler unit By activating the appropriate controls located on the machine s frontlet panel opt...

Page 9: ...at some free space is left all around the machine to make use and maintenance operations quick and easy Do not install the machine if it is wet or moist and wait until the machine is surely and comple...

Page 10: ...4 4 connect the other end of the tube up to the water mains Check to make sure that there are no obstructions in the mains 5 press the general switch the machine will automatically fill in water up t...

Page 11: ...herefore coffee dispensing is not recommended The interval comprised between 0 8 and 1 6 bar indicates that the pressure and the temperature internally to the boiler are at their ideal levels for coff...

Page 12: ...SPLAY MESSAGES 1 BLOCKI NG ALARMS Alarm Out of order When this message comes up on display it is possible to resort to Pushbutton 7 to access the maintenance mode by keeping it pressed in for 4 sec Pu...

Page 13: ...menu selection The sub menus available for selection are as follows 1 Doses Doses 2 Sales Sales 3 Temperature Temperature 4 Options Options 5 Timing and thresholds Timing and thresholds 6 Clock Clock...

Page 14: ...000 Lease number 00000 Second to last discharge 00 00 00 00 00 Last discharge 00 00 00 00 00 Description Unresettable Resettable Total selections 0 0 Strong coffee selections 0 0 Two strong coffee sel...

Page 15: ...ormat provided is hours minutes The hours go from 0 to 23 and the minutes go from 0 to 59 Start 1 Sets switch on time x Where 1 or 2 The format provided is hours minutes The hours go from 0 to 23 and...

Page 16: ...n continuously for the overall water timeout Said alarm is an auto reset alarm therefore if the water empty input is detected as being continuously closed for the overall water empty timeout the alarm...

Page 17: ...in the following ways Press the decaffeinated mode pre selection key Key 4 a second time if the group does not detect door opening and closing the group will not run a complete cycle at subsequent se...

Page 18: ...al is generated and the dispensing cycle is brought to an end The group timeout expire Timing and thresholds menu the E61 Group system stored signal is generated and the dispen sing cycle is brought t...

Page 19: ...after the adjustment operations cannot be taken into consideration If in the 3 subsequent selections the coffee dispensing time does not reach 18 3 if the coffee is less than 60 cc and 4 if the coffee...

Page 20: ...ack on again whereupon the fol lowing non amendable messages will come up on display T1 KEY VMC T5 VMC KEY Pressing key 1 will store the key data onto the VMC Pressing key 5 will store the VMC data on...

Page 21: ...ixed message Boiler fixed message I n phase B Switch off fixed message 9 0 MAI NTENANCE 9 1 SOFTW ARE FUNCTI ON MANAGEMENT KEY FUNCTI ONS The maintenance menu is accessed by keeping pushbutton 4 press...

Page 22: ...he resettable American coffee selections counter Strong Dekaf coff selections Displays the resettable decaffeinated strong coffee selections counter Standard deka coff selections Displays the resettab...

Page 23: ...fee container lid Lift and move the coffee container Fig 8 4 Remove screw 2 Fig 8 5 and lift the lid 1 Close the water mains supply tap Fig 8 6 Detach the tube Detach the electric connector Once the g...

Page 24: ...ut by the operator w ith the m achine pow ered dow n and unplugged from the power mains For any other type of anomaly or non specified machine inconveniency unplug the m achine from the pow er m ains...

Page 25: ...h alarm Please consult the resistance management paragraph under the operation section By the installation and service technician E21 Boiler load Boiler load alarm Please consult the boiler load m ana...

Page 26: ...set the decounter E49 HACCP HACCP decounter warning Each pump ma nagement activation decreases the counter that is displayed in the preventive action menu 6 When the decounter is down to zero the sign...

Page 27: ...Bia nc hive nding group...

Page 28: ......

Page 29: ...ed this form as formal report of first installation the BVG kindly asks you to fill this form in once the process of first installation of the unit has been performed and to return it back to us Pleas...

Page 30: ......

Page 31: ...e Use Maintenance manual attached to machines and on the www bianchindustry com eventual call back by the BVG Sender E mail Fax N to confirm the warranty being activated To be sent FAX 39 035 883304 o...

Page 32: ......

Page 33: ...elections for each button Button 8 to exit this mode 7 Press this button for 3 seconds to activate the automatic opening of the grinders 1 turn of the screw 8 ESCAPE exit maintenance mode Button Nr Fu...

Page 34: ...Cod 11112921 Ediz 10 2009...

Reviews: