14

M EN U 2  ( SALES)

Unreset t .t ot al select ions
-  

 

Displays t he unreset t able t ot al select ions  

 

 

 

count er. The m axim um  value is 16777251.

Tot al select ions 
-  

 

Displays t he reset t able t ot al select ions count er.  

 

 

The m axim um  value is 16777251.

St rong coff.select ions
-  

 

Displays t he reset t able, st rong coffee select ions  

 

 

count er. The m axim um  value is 65535.

2St rong coff.select ions
-  

 

Displays t he reset t able, t w o st rong coffees    

 

 

select ions count er. 

 

 

The m axim um  value is 65535.

St andard espr.coff.select ions
-  

 

Displays the resettable, standard espresso coffee  

 

 

select ions count er. The m axim um  value is    

 

 

65535.

2St andard espr.coff.select ions 
-  

 

Displays t he reset t able, t w o st andard espresso  

 

 

coffees select ions count er.

 

 

The m axim um  value is 65535.

Milk select ions
-  

 

Displays t he reset t able, m ilk select ions count er.  

 

 

The m axim um  value is 65535.

Am er. Coffee select ions   
-  

 

Displays t he reset t able, “Am erican coffee”   

 

 

 

select ions count er.

 

 

The m axim um  value is 65535.

Dekaf. coff. select ions
-  

 

Displays t he reset t able, decaffeinat ed coffee  

 

 

select ions count er.

 

 

The m axim um  value is 65535.

St andard deka.coff.select ions  
-  

 

Displays t he reset t able, st andard decaffeinat ed  

 

 

coffee select ions count er.

 

 

The m axim um  value is 65535.

Am erican deka.coff.select ions  
-  

 

Displays the resettable, Am erican decaffeinated  

 

 

coffee select ions count er. 

 

 

The m axim um  value is 65535.

Code 
- - - -  

 

Passw ord ent ry code is request ed t o access   

 

 

t he audit  dat a cancellat ion procedure.  

 

 

 

The m axim um  value is 9999.

Replace code? 
- -  

 

Asks for confirmation of possible replacement  

 

 

of t he passw ord ent ry code required t o access  

 

 

t he audit  dat a cancellat ion procedure.

 

 

The ent ry dat a allow ed here is:  NO or YES.

Code 
- - - -  

 

Set  a new password ent ry code for access t o t he  

 

 

audit  dat a cancellat ion procedure. 

 

 

The ent ry dat a allow ed here is:  0 t o 9999

 

 

Visible only if YES is set  under t he “ Replace   

 

 

Code” data field.

Set  t o zero? 
- -  

 

Confirm only if the audit data must be reset to  

 

 

zero.

 

 

The ent ry dat a allow ed here is:  NO or YES.

The  count ers  undergo  an  increm ent al  updat e  at   t he  end  of  t he 
dispensing cycle.

The audit  dat a are st ored bot h on t he ( red)  Audit  key and on t he 

VSPS.  A  .txt  format  file  is  generated  via  the  relative  windows 

program s. I t  is form at t ed as follow s:

 

AUDI T File:

Machine num ber   

 

000000

Lease num ber  

 

 

00000

Second t o last  discharge    

00/ 00/ 00  

00: 00

Last  discharge  

 

 

00/ 00/ 00  

00: 00

 

Descript ion  

 

     Unresettable     Resettable

Tot al select ions     

 

     

0  

    0

St rong coffee select ions    

     

0  

    0

Tw o st rong coffee select ions  

     

0  

    0

St andard espresso coffee select ions      

0  

    0

Tw o st andard espresso coffee select ions  

0  

    0

Milk select ions  

 

 

 

0  

    0

“Am erican coffee”  select ions  

 

0  

    0

Decaffeinat ed st rong coffee select ions  

0  

    0

Decaffeinat ed st andard espresso    

0  

    0

coffee select ions  

Decaffeinat ed “Am erican coffee”  select ions   0  

    0

The second to last discharge data field is set only if the clock chip 

was im plem ent ed for t he last  discharge.

The last discharge data field is set only if the clock chip is pro

-

vided.

M EN U 3  ( OPTI ON S)

Language
English  

Set s V.M. language. I t  is possible t o set  eit her  

 

 

[ I t alian, French, English, Spanish, Germ an,   

 

 

Port uguese,] . The m essage displayed in  

 

 

 

line 2 is message no. 0 in the message file.

Coffe disp. t im e 
- - .-  s   

Set s t he reference t im e for espresso coffee    

 

 

dispensing.

 

 

The ent ry dat a allow ed here is:  0.0 t o 35.0 s.

I ndependent  pum p
- -  

 

Enables independent  pum p m anagem ent .

 

 

The ent ry dat a allow ed here is:  NO or YES.

Machine num ber
- - - - - - -    

Set s t he m achine serial num ber

 

 

The ent ry dat a allow ed here is:  0 t o 9999999

Lease num ber
- - - - -  

 

Set s t he V.M. lease num ber

 

 

The ent ry dat a allow ed here is:  0÷ 65535.

Preset  Washing
- -  

 

Enables m achine cleaning cycle t im e set t ings,  

 

 

based on t he t im e ranges program m ed in t he  

 

 

m enu Clock   Wash cycles ( 6.2) .

 

 

The ent ry dat a allow ed here is:  NO or YES.

Wash cycle
- -  

 

Enables m achine wash cycle.

 

 

The ent ry dat a allow ed here is:  NO or YES.

Probe Sensit ivit y 
- - -  

 

Set s level t hreshold probe sensit ivit y.

 

 

The ent ry dat a allow ed here is:  20 t o 200 

 

 

 

( w here 20 is m ax sens. -  200 is m in. sens.)

Default  dat a?
- -  

 

Confirm whether default data is to be reinstated.  

 

 

The default data is the data specified in this   

 

 

m anual. Furt herm ore, t he reset t able sales    

 

 

dat a is set  back t o zero.

 

 

The ent ry dat a allow ed here is:  NO or YES.

M EN U 4  ( TI M I N G AN D  TH RESH OLD S)

Grinder t hreshold 
- - .-  

 

Grinder current  read- off t hreshold.

 

 

The ent ry dat a allow ed here is:  05.0 t o 18.0

Grinder t im eout
- - .-  s   

Set s grinder t im eout .

 

 

The ent ry dat a allow ed here is:  0.0 t o 25.5 s.

Group t im eout
- - .-  s   

Set s group t im eout .

 

 

The ent ry dat a allow ed here is:  0.0 t o 10.0 s.

Group speed
- -  

 

Set s group speed expressed in percent age.

 

 

The ent ry dat a allow ed here is:  20 t o 100

Esp. pum p t im eout
- - -  s 

 

Set s t he espresso pum p t im eout .

 

 

The ent ry dat a allow ed here is:  0 t o 250 s.

Summary of Contents for BVM 351

Page 1: ...BVM 3 5 1 CERT N 9191 BNVN UNI EN ISO 14001 2004 CERT N 9105 BNVD UNI EN ISO 9001 2000 USE AND MAINTENANCE MANUAL...

Page 2: ......

Page 3: ...75 2003 06 Special requirements for commercial dispensers and automatic vending machines EN ISO 11201 EN ISO 3744 Measurement of acoustic noise 2 ELECTROMAGNETI C COMPATI BI LI TY EMC EN 55014 1 Emis...

Page 4: ...ier recycling of the materials forming the equipment Any unauthorized disposal of the product by the user will imply the enforcement of the administrative sanctions as set out in Legislative Decree no...

Page 5: ...of all the necessary machine cleaning operations In the event of machine breakdowns the operator is required to contact the installation and service technicians accordingly I NSTALLATI ON TECHNI CI A...

Page 6: ...s right until the machine is actually stripped and scrapped In case of loss or damage of the present manual it is possible receive a new copy making application to the manufacturer with prior indicati...

Page 7: ...acilities with temperatures not less than 5 C It is pos sible to stack only up to three packages of the same machine on top of one another Avoid placing any other types of heavy packages on top of the...

Page 8: ...aled or maintenance free volumetric pump Water heating is provided via conductive thermal exchange in the boiler unit By activating the appropriate controls located on the machine s frontlet panel opt...

Page 9: ...at some free space is left all around the machine to make use and maintenance operations quick and easy Do not install the machine if it is wet or moist and wait until the machine is surely and comple...

Page 10: ...4 4 connect the other end of the tube up to the water mains Check to make sure that there are no obstructions in the mains 5 press the general switch the machine will automatically fill in water up t...

Page 11: ...herefore coffee dispensing is not recommended The interval comprised between 0 8 and 1 6 bar indicates that the pressure and the temperature internally to the boiler are at their ideal levels for coff...

Page 12: ...SPLAY MESSAGES 1 BLOCKI NG ALARMS Alarm Out of order When this message comes up on display it is possible to resort to Pushbutton 7 to access the maintenance mode by keeping it pressed in for 4 sec Pu...

Page 13: ...menu selection The sub menus available for selection are as follows 1 Doses Doses 2 Sales Sales 3 Temperature Temperature 4 Options Options 5 Timing and thresholds Timing and thresholds 6 Clock Clock...

Page 14: ...000 Lease number 00000 Second to last discharge 00 00 00 00 00 Last discharge 00 00 00 00 00 Description Unresettable Resettable Total selections 0 0 Strong coffee selections 0 0 Two strong coffee sel...

Page 15: ...ormat provided is hours minutes The hours go from 0 to 23 and the minutes go from 0 to 59 Start 1 Sets switch on time x Where 1 or 2 The format provided is hours minutes The hours go from 0 to 23 and...

Page 16: ...n continuously for the overall water timeout Said alarm is an auto reset alarm therefore if the water empty input is detected as being continuously closed for the overall water empty timeout the alarm...

Page 17: ...in the following ways Press the decaffeinated mode pre selection key Key 4 a second time if the group does not detect door opening and closing the group will not run a complete cycle at subsequent se...

Page 18: ...al is generated and the dispensing cycle is brought to an end The group timeout expire Timing and thresholds menu the E61 Group system stored signal is generated and the dispen sing cycle is brought t...

Page 19: ...after the adjustment operations cannot be taken into consideration If in the 3 subsequent selections the coffee dispensing time does not reach 18 3 if the coffee is less than 60 cc and 4 if the coffee...

Page 20: ...ack on again whereupon the fol lowing non amendable messages will come up on display T1 KEY VMC T5 VMC KEY Pressing key 1 will store the key data onto the VMC Pressing key 5 will store the VMC data on...

Page 21: ...ixed message Boiler fixed message I n phase B Switch off fixed message 9 0 MAI NTENANCE 9 1 SOFTW ARE FUNCTI ON MANAGEMENT KEY FUNCTI ONS The maintenance menu is accessed by keeping pushbutton 4 press...

Page 22: ...he resettable American coffee selections counter Strong Dekaf coff selections Displays the resettable decaffeinated strong coffee selections counter Standard deka coff selections Displays the resettab...

Page 23: ...fee container lid Lift and move the coffee container Fig 8 4 Remove screw 2 Fig 8 5 and lift the lid 1 Close the water mains supply tap Fig 8 6 Detach the tube Detach the electric connector Once the g...

Page 24: ...ut by the operator w ith the m achine pow ered dow n and unplugged from the power mains For any other type of anomaly or non specified machine inconveniency unplug the m achine from the pow er m ains...

Page 25: ...h alarm Please consult the resistance management paragraph under the operation section By the installation and service technician E21 Boiler load Boiler load alarm Please consult the boiler load m ana...

Page 26: ...set the decounter E49 HACCP HACCP decounter warning Each pump ma nagement activation decreases the counter that is displayed in the preventive action menu 6 When the decounter is down to zero the sign...

Page 27: ...Bia nc hive nding group...

Page 28: ......

Page 29: ...ed this form as formal report of first installation the BVG kindly asks you to fill this form in once the process of first installation of the unit has been performed and to return it back to us Pleas...

Page 30: ......

Page 31: ...e Use Maintenance manual attached to machines and on the www bianchindustry com eventual call back by the BVG Sender E mail Fax N to confirm the warranty being activated To be sent FAX 39 035 883304 o...

Page 32: ......

Page 33: ...elections for each button Button 8 to exit this mode 7 Press this button for 3 seconds to activate the automatic opening of the grinders 1 turn of the screw 8 ESCAPE exit maintenance mode Button Nr Fu...

Page 34: ...Cod 11112921 Ediz 10 2009...