15
Wat er load t im eout
- - - s
Set s t he wat er load m anagem ent t im eout .
The ent ry dat a allow ed here is: 0 t o 250 s.
Boiler load t im eout
- - - s
Set s t he heat er load m anagem ent t im eout .
The ent ry dat a allow ed here is: 0 t o 250 s.
I nd. pum p t im eout
- - s
Set s t he independent pum p t im eout .
The ent ry dat a allow ed here is: 0 t o 60 s.
Cleaning cycle t im e
- - .- s
Set s t he cleaning cycle t im e.
The ent ry dat a allow ed here is: 0.0 t o 25.5 s.
M EN U 5 ( CLOCK)
Clock
Set s hours/ m inut es
The sub m enus available for select ion are as follow s:
1. Set dat a ( “ Set dat a ” )
2. Set hours and m inut es ( “ Set hrs/ m inut es ” )
3. Wash cycles ( “ Washing ” )
4. Sw it ch off ( “ Sw it ch off ” )
M EN U 5 .1 ( SET D ATE)
Set dat e
- - / - - / - -
Changes t he clock chip dat e.
The form at provided is: dd/ m m / yy .
The days go from 1 t o 31, t he m ont hs from 1
t o 12 and t he years from 0 t o 99.
M EN U 5 .2 ( SET H OURS AN D M I N UTES)
Set s hours/ m inut es
- - : - -
Changes t he clock chip t im e.
The form at provided is: hours: m inut es.
The hours go from 0 t o 23 and t he m inut es
go from 0 t o 59.
M EN U 5 .3 ( CLEAN I N G)
Cleaning “ x ”
- - : - -
Set s t he “ x ” cleaning cycle t im e.
Where “ x” = 1 or 2.
The form at provided is: hours: m inut es.
The hours go from 0 t o 23 and t he m inut es go
from 0 t o 59.
M EN U 5 .4 ( SW I TCH OFF)
St op 1
- - : - -
Set s m achine St op 1 or St op 2.
The form at provided is: hours: m inut es.
The hours go from 0 t o 23 and t he m inut es go
from 0 t o 59.
St art 1
- - : - -
Set s sw it ch- on t im e “ x ”. Where × = 1 or 2
The form at provided is: hours: m inut es.
The hours go from 0 t o 23 and t he m inut es go
from 0 t o 59.
St op 2
- - : - -
Set s m achine St op 2 × . Where “ × ” = 1 or 2.
The form at provided is: hours: m inut es.
The hours go from 0 t o 23 and t he m inut es go
from 0 t o 59.
St art 2
- - : - -
Set s t he t im e for sw it ch- on “ × ”.
Where “ × ” = 1 or 2
The form at provided is: hours: m inut es.
The hours go from 0 t o 23 and t he m inut es go
from 0 t o 59.
M EN U 6 ( PREV EN TI V E ACTI ON )
Coffee grounds
- -
Displays coffee grounds decount er value.
Wat er t reat m ent unit
- - - - - - -
Set s t he wat er t reat m ent unit decount er value.
The ent ry dat a allow ed here is: 0 t o 9999999
Coffee grinder
- - - - - - -
Set s t he coffee grinder decount er value.
The ent ry dat a allow ed here is: 0 t o 9999999
Coffee filters
- - - - - - -
Sets the coffee filter decounter value.
The ent ry dat a allow ed here is: 0 t o 9999999
Elect ro valves
- - - - - - -
Set s t he elect ro valve decount er value.
The ent ry dat a allow ed here is: 0 t o 9999999
Seals
- - - - - - -
Sets the filter seals decounter value.
The ent ry dat a allow ed here is: 0 t o 9999999
Boiler
- - - - - - -
Set s t he boiler decount er value.
The ent ry dat a allow ed here is: 0 t o 9999999
HACCP
- - - - - - -
Set s t he HACCP sanit isat ion decount er value.
The ent ry dat a allow ed here is: 0 t o 9999999
Coffee grounds recharge
- - - - - - -
Set s t he coffee grounds recharge lim it value.
The ent ry dat a allow ed here is: 0 t o 50