7
AudiaFUSION REAR PANEl
Please note that CobraNet limits network extensions to seven hops (one-way transmissions) within a network.
The primary and secondary CobraNet ports are redundant. Each connector provides two LEDs that indicate Ethernet link and network
activity (see table below).
Table 1 . CobraNet interface status LEDs
AM-600
AM-600 is the Amplifier Module card. An AudiaFUSION chassis can be populated with up to eight AM-600 cards.
Output
Use the yellow plug-in barrier strip connectors to connect loudspeaker level outputs. If stranded speaker wire is used, be sure to incorporate
all strands into the connector, as stray strands can short to the adjacent terminal or chassis. Do not leave excessive bare wire outside
the terminals, as this can lead to shorts.
Left LED
Right LED
Description
None
None
No data connectivity. .
Green
None
Link established.
Green
Flashing
amber
Link established and CobraNet activity detected; the unit is acting as a CobraNet performer.
Flashing
green
Flashing
amber
Link established and CobraNet activity detected; the unit is operating as a CobraNet conductor.
Flashing
amber
Flashing
amber
CobraNet fault. Check cabling and configuration for errors.
Please note:
AudiaFUSION is a powerful amplifier and can
damage loudspeakers. Please treat the outputs as you would
AC mains power outlets. Always check the loudspeaker’s
continuous and peak power capabilities and match the amplifier
settings accordingly.