6
AudiaFUSION REAR PANEl
Figure 3 . Rear Panel Layout
Serial Control Port
After initial programming and configuration, AudiaFUSION may be controlled by third-party control systems such as AMX
®
or Crestron
®
using the Serial Control Port. External devices may also be controlled or signaled via the Serial Control Port by utilizing Command String
blocks within the Audia system design. The port is a DB9 female with pin 2 [RXD], pin 3 [TXD], and pin 5 [GND] connected. AudiaFUSION is
an RS-232 DCE device. The default settings are 38400, 8, N, 1, None. The baud rate is adjustable in the Audia software using the Device
Maintenance dialog window. The other serial port settings are not adjustable.
Please note:
There is no hardware flow control. Flow control
must be managed in control software.
Power Entrance
The Power Entrance provides for connection of the appropriate power cord (included with unit). A switch selects the operating voltage for
the power supply, 110–120V or 220–240V at 50/60 Hz.
NM-1
NM-1 is the Network Module that is included with AudiaFUSION. It provides Ethernet connectivity for programming and control, the
CobraNet interface for digital I/O, and logic ports for the device failover functionality.
Reset Button
Reset button, when held down for 5 seconds, performs a chassis restart. The Status indicator will flash amber during restart and will turn
solid green once the process is complete.
Logic I/O
The Logic I/O connector on the NM-1 facilitates redundant device failover only. It is not a general-purpose contact closure interface.
See the Amplifier-to-Amplifier Failover section below.
Ethernet
AudiaFUSION uses Ethernet for system programming and control. Programming is accomplished using Audia software provided with
each unit. Audia software is for PC computers with Windows
®
XP Professional/Vista operating system (required). The PC computer must
have a network card installed that supports 10/100Base-T Ethernet. A 10/100Base-T Ethernet switch (not repeater hub) is required when
networking multiple units. AudiaFUSION uses standard CAT5, CAT5e, CAT6, or CAT7 cabling, which has a specified maximum length of
100 meters. Additional Ethernet switches and/or fiber-optic cable can be used to further extend distances between units on a network.
CobraNet
The CobraNet interface in AudiaFUSION supports up to 32 simultaneous channels of digital audio (16-in, 16-out) over Fast Ethernet
and is compatible with other CobraNet compliant devices. Therefore, AudiaFUSION can be networked with CobraNet products from other
manufacturers, expanding the system configuration capabilities. A 10/100Base-T Ethernet switch (not repeater hub) is required when
networking multiple units. CobraNet utilizes standard CAT5, CAT5e, CAT6, or CAT7 cabling, which has a specified maximum length of
100 meters. Additional Ethernet switches and/or fiber-optic cable can be used to further extend distances between units on a network.
110-120/220-240V~
50/60Hz 2400WATT
BIAMP SYSTEMS
220-240V: T 12 H, 250V
110-120V: T 20 H, 250V
CAUTION
RISK OF ELECTRICAL SHOCK.
DO NOT OPEN.
52SJ
115V
115V
FUS
E
E
S
U
F
OUTPUT
Class 2
Wir
ing
AM-600
OUTPUT
Class 2
Wir
ing
AM-600
OUTPUT
Class 2
Wir
ing
AM-600
OUTPUT
Class 2
Wir
ing
AM-600
OUTPUT
Class 2
Wir
ing
AM-600
OUTPUT
Class 2
Wir
ing
AM-600
OUTPUT
Class 2
Wir
ing
AM-600
OUTPUT
Class 2
Wir
ing
AM-600
NM-1
Secondar
y
YEL
: In use/Conducto
r
GRN:
Link/Activity
CobraNet
®
Connections Only
Pr
imar
y
Ether
net
Logic I/O
Class 2
Wir
ing
1
2
3
4
LEDs
1
2
3
4
5
6
7
8
9
10
MODEL AudiaFUSION
SERIAL CONTROL PORT
110-120/220-240V~
50/60Hz 2400WATT
BIAMP SYSTEMS
220-240V: T 12 H, 250V
110-120V: T 20 H, 250V
CAUTION
RISK OF ELECTRICAL SHOCK.
DO NOT OPEN.
52SJ
Audia FUSION chassis composite
(Pantone Black)
6/30/09 BG
MODEL AudiaFUSION
Summary of Contents for AUDIAFUSION
Page 2: ...IMPORTANT SAFETY INSTRUCTIONS ...
Page 16: ...15 15 compliance ...
Page 17: ...16 IMPORTANT SAFETY INSTRUCTIONS ...