AudiaFUSION REAR PANEl

Figure 3 . Rear Panel Layout

Serial Control Port

After initial programming and configuration, AudiaFUSION may be controlled by third-party control systems such as AMX

®

 or Crestron

®

 

using the Serial Control Port. External devices may also be controlled or signaled via the Serial Control Port by utilizing Command String 
blocks within the Audia system design. The port is a DB9 female with pin 2 [RXD], pin 3 [TXD], and pin 5 [GND] connected. AudiaFUSION is 
an RS-232 DCE device. The default settings are 38400, 8, N, 1, None. The baud rate is adjustable in the Audia software using the Device 
Maintenance dialog window. The other serial port settings are not adjustable. 

Please note:

 There is no hardware flow control. Flow control 

must be managed in control software.

Power Entrance

The Power Entrance provides for connection of the appropriate power cord (included with unit). A switch selects the operating voltage for 
the power supply, 110–120V or 220–240V at 50/60 Hz.

NM-1

NM-1 is the Network Module that is included with AudiaFUSION. It provides Ethernet connectivity for programming and control, the 
CobraNet interface for digital I/O, and logic ports for the device failover functionality. 

Reset Button

Reset button, when held down for 5 seconds, performs a chassis restart. The Status indicator will flash amber during restart and will turn 

solid green once the process is complete.

Logic I/O

The Logic I/O connector on the NM-1 facilitates redundant device failover only. It is not a general-purpose contact closure interface. 

 

See the Amplifier-to-Amplifier Failover section below.

Ethernet

AudiaFUSION uses Ethernet for system programming and control. Programming is accomplished using Audia software provided with 

each unit. Audia software is for PC computers with Windows

®

 XP Professional/Vista operating system (required). The PC computer must 

have a network card installed that supports 10/100Base-T Ethernet. A 10/100Base-T Ethernet switch (not repeater hub) is required when 
networking multiple units. AudiaFUSION uses standard CAT5, CAT5e, CAT6, or CAT7 cabling, which has a specified maximum length of 
100 meters. Additional Ethernet switches and/or fiber-optic cable can be used to further extend distances between units on a network.

CobraNet

The CobraNet interface in AudiaFUSION supports up to 32 simultaneous channels of digital audio (16-in, 16-out) over Fast Ethernet 

and is compatible with other CobraNet compliant devices. Therefore, AudiaFUSION can be networked with CobraNet products from other 

manufacturers, expanding the system configuration capabilities. A 10/100Base-T Ethernet switch (not repeater hub) is required when 
networking multiple units. CobraNet utilizes standard CAT5, CAT5e, CAT6, or CAT7 cabling, which has a specified maximum length of 
100 meters. Additional Ethernet switches and/or fiber-optic cable can be used to further extend distances between units on a network. 

110-120/220-240V~

50/60Hz  2400WATT

BIAMP SYSTEMS

220-240V: T 12 H, 250V

110-120V: T 20 H, 250V

CAUTION

RISK OF ELECTRICAL SHOCK.

DO NOT OPEN.

52SJ

115V

115V

FUS

E

E

S

U

F

OUTPUT

Class 2 

Wir

ing

AM-600

OUTPUT

Class 2 

Wir

ing

AM-600

OUTPUT

Class 2 

Wir

ing

AM-600

OUTPUT

Class 2 

Wir

ing

AM-600

OUTPUT

Class 2 

Wir

ing

AM-600

OUTPUT

Class 2 

Wir

ing

AM-600

OUTPUT

Class 2 

Wir

ing

AM-600

OUTPUT

Class 2 

Wir

ing

AM-600

NM-1

Secondar

y

YEL

: In use/Conducto

r

GRN:

 Link/Activity

CobraNet

®

 Connections Only

Pr

imar

y

Ether

net

Logic I/O

Class 2 

Wir

ing

1

2

3

4

LEDs

1

2

3

4

5

6

7

8

9

10

MODEL AudiaFUSION

SERIAL CONTROL PORT

110-120/220-240V~

50/60Hz  2400WATT

BIAMP SYSTEMS

220-240V: T 12 H, 250V

110-120V: T 20 H, 250V

CAUTION

RISK OF ELECTRICAL SHOCK.

DO NOT OPEN.

52SJ

Audia FUSION chassis composite

(Pantone Black)

6/30/09  BG

MODEL AudiaFUSION

Summary of Contents for AUDIAFUSION

Page 1: ...Audia AudiaFUSION Manual Biamp Systems 9300 S W Gemini Drive Beaverton OR 97008 USA 1 503 641 7287 www biamp com ...

Page 2: ...IMPORTANT SAFETY INSTRUCTIONS ...

Page 3: ...s Indicators 5 rear panel 6 9 Serial Control Port 6 Power Entrance 6 NM 1 6 Logic I O 6 Ethernet 6 CobraNet 6 AM 600 7 Output 7 Amplifier to Amplifier Failover 8 Channel to Channel Failover 9 AudiaFUSION AM 600 CARD specifications 10 115 VAC Current Draw and Heat Output 11 Block diagram 12 warranty 13 ...

Page 4: ... processing resources are allocated as needed making the whole system more efficient alarm activity signal 1 signal 2 status ais power FEATURES Modular based design Amplification modules have software configurable power levels load options 8 amplification modules per frame with 100W to 600 Watts per module maximum of 2400W per chassis 70 V or 100 V with direct drive capability or low impedance 4 o...

Page 5: ... occurred Two types of channel faults can be reported depending on the severity of the problem Amber indicates a Warning which means that some aspect of the AM 600 amplifier module is not performing within normal specification Audio may still be passing but if the condition causing the Warning is not corrected channel failure may occur Red indicates an Alarm which means that some aspect of the AM ...

Page 6: ...ay no longer be passing through the device Use the Audia software to determine the specific type of chassis warning or alarm that has occurred Activity is a tri color LED that illuminates to show the configuration status of the AudiaFUSION unit If the LED is dark there is no configuration in the unit A green LED indicates that the unit is configured and an amber LED indicates that the unit is conf...

Page 7: ...or PC computers with Windows XP Professional Vista operating system required The PC computer must have a network card installed that supports 10 100Base T Ethernet A 10 100Base T Ethernet switch not repeater hub is required when networking multiple units AudiaFUSION uses standard CAT5 CAT5e CAT6 or CAT7 cabling which has a specified maximum length of 100 meters Additional Ethernet switches and or ...

Page 8: ...or as stray strands can short to the adjacent terminal or chassis Do not leave excessive bare wire outside the terminals as this can lead to shorts Left LED Right LED Description None None No data connectivity Green None Link established Green Flashing amber Link established and CobraNet activity detected the unit is acting as a CobraNet performer Flashing green Flashing amber Link established and...

Page 9: ...he primary amplifier to logic 3 of the redundant amplifier connect logic 3 of the primary amplifier to logic 4 of the redundant amplifier Leave logic 1 and 2 disconnected The redundant amplifier can be wired in parallel to the existing speaker line or connected to a redundant speaker line see figure below Relays isolate the output terminals on the secondary AudiaFUSION unit Relays are normally ope...

Page 10: ...e redundant channel can be wired in parallel to the existing speaker line shown above or connected to a redundant speaker line The primary amplifier module will resume control after the fault condition is cleared and the unit is re powered OUTPUT Class 2 Wiring AM 600 OUTPUT Class 2 Wiring AM 600 1 2 OUTPUT Class 2 Wiring AM 600 OUTPUT Class 2 Wiring AM 600 1 2 Primary Redundant Redundant Wiring P...

Page 11: ... 101 dB 102 dB 103 dB 102 dB 102 dB 103 dB 102 dB 103 dB 104 dB Intermodulation distortion SMPTE 0 2 Inter channelIsolation 75 dB 20 Hz 20 kHz full power out DC offset 10mV 1 In chassis with fans running normally and unrestricted intake and exhaust AudiaFUSION SPECIFICATIONS Inputs 20 bits 48 kHz supported CobraNet latency 5 1 3 2 2 3 or 1 1 3 ms software configurable Overall Dimensions Height Wid...

Page 12: ...AMPLIFIER CARD CLASS D AMPLIFIER DSP DSP Display CobraNet uC CobraNet Audio Ethernet Control 10 100 ETHERNET FAN CONTROL FAN 1 SLOT 1 SLOT 2 SLOT 3 SLOT 4 SLOT 5 SLOT 6 SLOT 7 SLOT 8 TEMPERATURE IMPEDANCE MONITORING DC DETECTION I V FAN 2 RS 232 LOGIC Serial I O Logic I O ...

Page 13: ... cards 0 0 3 106 NA NA NA NA NA NA 100 1 0 4 143 0 7 227 0 9 244 1 6 406 200 1 0 4 143 0 8 239 1 3 271 2 7 491 300 1 0 4 143 1 0 251 1 6 300 3 8 590 400 1 0 4 143 1 1 263 2 0 333 4 9 668 500 1 0 4 143 1 3 278 2 4 356 6 1 788 600 1 0 4 143 1 4 297 2 8 413 7 3 910 700 2 0 5 177 1 8 418 3 4 551 8 9 1211 800 2 0 5 177 2 0 430 3 8 577 10 0 1296 900 2 0 5 177 2 1 442 4 2 607 11 1 1395 1000 2 0 5 177 2 2...

Page 14: ...any manner that does not comply with BIAMP Systems recommendations 4 Electro mechanical fans electrolytic capacitors gooseneck microphones cords connecting handheld microphones hard drives displays and normal wear and tear of items such as paint knobs handles keypads and covers are not covered under this warranty All server based devices are warranted for 3 years only 5 This warranty is in lieu of...

Page 15: ...t 8 VoIP 2 Voltage Control Box Product Description Audio Digital Signal Processors and Control Accessories Applicable EC Directives Applicable Harmonized Standards LVD Directive 2006 95 EC Safety EN 60065 2002 EMC Directive 2004 108 EC Emissions EN 55103 1 1996 Environment E2 Immunity EN 55103 2 1996 R TTE Directive 1999 5 EC Terminal Equipment AudiaFLEX with TI 2 only Special Considerations for P...

Page 16: ...15 15 compliance ...

Page 17: ...16 IMPORTANT SAFETY INSTRUCTIONS ...

Page 18: ...17 IMPORTANT SAFETY INSTRUCTIONS ...

Page 19: ...18 IMPORTANT SAFETY INSTRUCTIONS ...

Reviews: