background image

3

AudiaFUSION

AudiaFUSION is the newest member of the Audia

®

 family, bringing together open-architecture DSP, Multi-Channel Amplifier technology, 

and device- and load-monitoring capabilities. AudiaFUSION features an 8-channel modular amplifier, 16x16 I/O via CobraNet

®

 and DSP 

with support for channel-to-channel and device-to-device failover. AudiaFUSION can support up to 8 amplifier cards that are individually 
software configurable from 100-600 watts for up to 2400 watts of power, with software-selectable 70V, 100V and low impedance outputs 

per card. Intuitive software provides audio system design via PC and allows easy selection, viewing and calibration of numerous audio 

components: mixers, combiners, matrixes, equalizers, filters, crossovers, dynamics, routers, delays, meters, generators, diagnostic tools, 

and more. Once a system design is compiled, it is downloaded into AudiaFUSION, where it can be controlled via AMX,

®

 Crestron,

®

 other 

third-party control system, or via computer running daVinci™ control software. When installed in a system together, AudiaFLEX and Audia

-

FUSION processing resources are allocated as needed, making the whole system more efficient. .

alarm

activity

signal 1
signal 2

status

ais

power

FEATURES

Modular based design

• 

 Amplification modules have software configurable power 

• 

levels/load options

 

– 8 amplification modules per frame with 100W to 600 Watts 

 

   per module (maximum of 2400W per chassis)

 

– 70 V or 100 V with direct drive capability, or low-impedance   

 

   (4 or 8Ω) operation

 

–  Maximum of 2400 watts of power in 3 rack unit device
TCP/IP Network controllable

• 

 LED Indication:

 

• 

– Signal present 

– Peak present 

– Clip present 

– Heat sink temperature fault 

– Amplifier failure

 

– Fan stuck-rotor

Internal amplifier module failover mode

• 

Entire device failover mode

• 

Software Monitoring Features: 

• 

– Peak present 

– Heatsink temperature value, warning and fault 

– Short circuit on output 

– Amplifier failure

 

– Impedance min/max threshold warning

 

– Excessive clipping

 

– Fan stuck-rotor

Seamless integration with CobraNet-enabled Audia systems

• 

CobraNet Interface (16 channels in/16 channels out)

• 

 CobraNet latency 5-1/3, 2-2/3 or 1-1/3 ms, 

 

• 

software configurable
Dual Ethernet ports for redundancy

• 

Selectable 115/230 volt operation

• 

 Control via RED-1, daVinci or third party control systems

• 

CE

• 

 marked, 

UL

 listed and 

RoHS

 compliant

Covered by 

• 

BIAMP

 Systems’ five-year warranty

Summary of Contents for AUDIAFUSION

Page 1: ...Audia AudiaFUSION Manual Biamp Systems 9300 S W Gemini Drive Beaverton OR 97008 USA 1 503 641 7287 www biamp com ...

Page 2: ...IMPORTANT SAFETY INSTRUCTIONS ...

Page 3: ...s Indicators 5 rear panel 6 9 Serial Control Port 6 Power Entrance 6 NM 1 6 Logic I O 6 Ethernet 6 CobraNet 6 AM 600 7 Output 7 Amplifier to Amplifier Failover 8 Channel to Channel Failover 9 AudiaFUSION AM 600 CARD specifications 10 115 VAC Current Draw and Heat Output 11 Block diagram 12 warranty 13 ...

Page 4: ... processing resources are allocated as needed making the whole system more efficient alarm activity signal 1 signal 2 status ais power FEATURES Modular based design Amplification modules have software configurable power levels load options 8 amplification modules per frame with 100W to 600 Watts per module maximum of 2400W per chassis 70 V or 100 V with direct drive capability or low impedance 4 o...

Page 5: ... occurred Two types of channel faults can be reported depending on the severity of the problem Amber indicates a Warning which means that some aspect of the AM 600 amplifier module is not performing within normal specification Audio may still be passing but if the condition causing the Warning is not corrected channel failure may occur Red indicates an Alarm which means that some aspect of the AM ...

Page 6: ...ay no longer be passing through the device Use the Audia software to determine the specific type of chassis warning or alarm that has occurred Activity is a tri color LED that illuminates to show the configuration status of the AudiaFUSION unit If the LED is dark there is no configuration in the unit A green LED indicates that the unit is configured and an amber LED indicates that the unit is conf...

Page 7: ...or PC computers with Windows XP Professional Vista operating system required The PC computer must have a network card installed that supports 10 100Base T Ethernet A 10 100Base T Ethernet switch not repeater hub is required when networking multiple units AudiaFUSION uses standard CAT5 CAT5e CAT6 or CAT7 cabling which has a specified maximum length of 100 meters Additional Ethernet switches and or ...

Page 8: ...or as stray strands can short to the adjacent terminal or chassis Do not leave excessive bare wire outside the terminals as this can lead to shorts Left LED Right LED Description None None No data connectivity Green None Link established Green Flashing amber Link established and CobraNet activity detected the unit is acting as a CobraNet performer Flashing green Flashing amber Link established and...

Page 9: ...he primary amplifier to logic 3 of the redundant amplifier connect logic 3 of the primary amplifier to logic 4 of the redundant amplifier Leave logic 1 and 2 disconnected The redundant amplifier can be wired in parallel to the existing speaker line or connected to a redundant speaker line see figure below Relays isolate the output terminals on the secondary AudiaFUSION unit Relays are normally ope...

Page 10: ...e redundant channel can be wired in parallel to the existing speaker line shown above or connected to a redundant speaker line The primary amplifier module will resume control after the fault condition is cleared and the unit is re powered OUTPUT Class 2 Wiring AM 600 OUTPUT Class 2 Wiring AM 600 1 2 OUTPUT Class 2 Wiring AM 600 OUTPUT Class 2 Wiring AM 600 1 2 Primary Redundant Redundant Wiring P...

Page 11: ... 101 dB 102 dB 103 dB 102 dB 102 dB 103 dB 102 dB 103 dB 104 dB Intermodulation distortion SMPTE 0 2 Inter channelIsolation 75 dB 20 Hz 20 kHz full power out DC offset 10mV 1 In chassis with fans running normally and unrestricted intake and exhaust AudiaFUSION SPECIFICATIONS Inputs 20 bits 48 kHz supported CobraNet latency 5 1 3 2 2 3 or 1 1 3 ms software configurable Overall Dimensions Height Wid...

Page 12: ...AMPLIFIER CARD CLASS D AMPLIFIER DSP DSP Display CobraNet uC CobraNet Audio Ethernet Control 10 100 ETHERNET FAN CONTROL FAN 1 SLOT 1 SLOT 2 SLOT 3 SLOT 4 SLOT 5 SLOT 6 SLOT 7 SLOT 8 TEMPERATURE IMPEDANCE MONITORING DC DETECTION I V FAN 2 RS 232 LOGIC Serial I O Logic I O ...

Page 13: ... cards 0 0 3 106 NA NA NA NA NA NA 100 1 0 4 143 0 7 227 0 9 244 1 6 406 200 1 0 4 143 0 8 239 1 3 271 2 7 491 300 1 0 4 143 1 0 251 1 6 300 3 8 590 400 1 0 4 143 1 1 263 2 0 333 4 9 668 500 1 0 4 143 1 3 278 2 4 356 6 1 788 600 1 0 4 143 1 4 297 2 8 413 7 3 910 700 2 0 5 177 1 8 418 3 4 551 8 9 1211 800 2 0 5 177 2 0 430 3 8 577 10 0 1296 900 2 0 5 177 2 1 442 4 2 607 11 1 1395 1000 2 0 5 177 2 2...

Page 14: ...any manner that does not comply with BIAMP Systems recommendations 4 Electro mechanical fans electrolytic capacitors gooseneck microphones cords connecting handheld microphones hard drives displays and normal wear and tear of items such as paint knobs handles keypads and covers are not covered under this warranty All server based devices are warranted for 3 years only 5 This warranty is in lieu of...

Page 15: ...t 8 VoIP 2 Voltage Control Box Product Description Audio Digital Signal Processors and Control Accessories Applicable EC Directives Applicable Harmonized Standards LVD Directive 2006 95 EC Safety EN 60065 2002 EMC Directive 2004 108 EC Emissions EN 55103 1 1996 Environment E2 Immunity EN 55103 2 1996 R TTE Directive 1999 5 EC Terminal Equipment AudiaFLEX with TI 2 only Special Considerations for P...

Page 16: ...15 15 compliance ...

Page 17: ...16 IMPORTANT SAFETY INSTRUCTIONS ...

Page 18: ...17 IMPORTANT SAFETY INSTRUCTIONS ...

Page 19: ...18 IMPORTANT SAFETY INSTRUCTIONS ...

Reviews: