When testing ISDN wiring, any resistive terminators
should be switched out of the circuit or disconnected.
Failure to do so could lead to erroneous test results.
The left side of the display shows information about the test per-
formed and the status of the test result.
The first line shows the unique identity of the active remote
unit connected to the far end (in this case, ID1). There are 15
additional active remote units available as optional accessories
(ID#2 to ID#16).
The test status,
PASS
is indicated on the second line. A test
PASS is confirmed by a double beep from the main unit and a
double green flash on the LED of the active remote unit.
Next, information about the test type selected, along with a mea-
sured value of the cable length, and an indication of the current
VP setting is displayed.
If a fault is found an appropriate message will be displayed,
along with a warning tone on the main unit, and a red flashing
LED on the remote unit.
ID:1
Pass
TIA568
L=103m
Vp=79%
Accept
No
Yes
A2111/0004
1
2
4
5
4
1
2
3
4
Shows the address identification which will be stored on
acceptance.
5
Gives the option of storing the results under the number shown by
pressing the button
or aborting by pressing button . If is
pressed the option is given to change the address.
5.4 Test Pass/OK Screen