In the event of a multiple fault, or a cable or link with more than one fault on
it, the tester will report the faults in the following order of priority.
• Shorts
• Reversals
• Opens
For example, on a cable with an Open on pin 3 and a Short between
pins 7 and 8, only the Short in pins 7 and 8 will be reported.
If a wire map test is performed without a remote unit connected at the far
end, the following screen will be displayed:
5.5.3 Multiple Faults
5.5.4 Missing Remote
missing remote unit