FAULT FINDING CHART
PROBLEM
CHECKS
SOLUTIONS
1. The monitor does not
switch on.
1) Make sure that the
machine is plugged in,
the ON/OFF switch in
position 1 and that the
safety key is inserted.
1) Plug the machine into
the mains supply. Set the
switch to position 1 and
insert the safety key.
The monitor switches on
but the motor fails to
start.
2) Check that the current
limiter is pressed in.
2) Switch the machine off
and press the circuit
breaker in. Lubricate the
treadmill band.
Walking motion is jerky
on the treadmill.
3.a) Check that the belt is
lubricated.
3.b) Check the tension on
the sliding belt.
3.c) Check the tension on
the drive belt.
3.a) Lubricate the sliding
belt.
3.b) Adjust the belt
tension.
3.c) Adjust the drive belt
tension.
The machine stops (the
breaker trips).
4) Check that the band is
lubricated.
4) Reset the overload
button with the On /Off
switch at „0“ and lubricate
the treadmill band.
Electrical shocks through
the handrail.
5)
Check
that
the
machine is plugged into
an earthed mains socket.
5) Plug the machine into
an earthed mains socket.
The treadmill belt skews
off centre.
6.a) Check that the
machine is level on the
floor.
6.b) Check that the
machine
does
not
wobble.