21. Use
UP/DOWN
button to view onscreen
prompts.
22. Press
Y
button and following screen shows:
23. Actuate the pedal gently to raise the pressure to 20-24 bar and keep it for 5s.
24. Follow onscreen instructions to complete operation of current phase:
- The fill level of wheel brake circuit HZ2 (secondary brake circuit) is in order.
- Release brake pedal.
- Checking fill status of wheel brake circuit HZ1 (primary brake circuit).
25. Press Y button or gently actuate and then release the pedal to continue, and the device starts to
communicate with the vehicle.