PROGRAMMING MENU
MAIN
S ELECTION
DES CRIPTION
DEFAULT
RANGE
PARAM >
OPEN DELAY TIME
Motor 2 opening delay in s econds
1
0-10
Motor 1 clos ing delay in s econds
1
0-10
TCA
Auto-clos e time adjus tment in s econds
10
1-180
Traffic zone clear time adjus tment in s econds
40
1-180
S lowdown s tarting dis tance from end of open travel expres s ed in percentage
10
0-50
S lowdown s tarting dis tance from end of clos e travel expres s ed in percentage
10
0-50
S lowdown s tarting dis tance from end of open and clos e travel expres s ed in percentage
15
0-50
OP. FORCE
Percentage of opening force exerted over the AUTOS ET value before obs truction is s ens ed
50
1-99
Percentage of clos ing force exerted over the AUTOS ET value before obs truction is s ens ed
50
1-99
OP S PEED
Motor opening s peed expres s ed in percentage
99
15-99
CL S PEED
Motor clos ing s peed expres s ed in percentage
99
15-99
S LOW SPEED
S lowdown s peed expres s ed in percentage from maximum s peed.
25
15-99
LOGIC >
MOTOR TYPE
1=Eli 250; 2=Phobos BT, 3=Igea BT
0
0-3
TCA
Timer to Clos e Automatically. 0=OFF / 1=ON
0
0-1
Clos es when s ens ors are cleared. 0=OFF / 1=ON
0
0-1
STEP-BY-STEP MOVEMENT *
Determines how the s ys tem reacts when a START command is received during operation
0
0-2
Gate running output (AUX value=6) clos es 3 s ec. before gate movement. 0=OFF / 1=ON
0
0-1
HOLD-TO-RUN
Requires continuous OPEN or CLOS E command input for gate to operate. 0=OFF / 1=ON
0
0-2
Ignores START input during the opening cycle. 0=OFF / 1=ON
0
0-1
Ignores the S TART input while counting down for automatic clos ing. 0=OFF / 1=ON
0
0-1
Ignores the S TART input during the clos ing cycle. 0=OFF / 1=ON
0
0-1
RAM BLOW C. OP
Pus hes gate agains t phys ical s top before opening
0
0-1
RAM BLOW C. CL
Pus hes gate agains t phys ical s top before clos ing
0
0-1
BLOC PERS IS T
Hourly pus h agains t phys ical s top
0
0-1
Pus hes gate agains t phys ical s top for .5 s econds after clos e limit has been reached.
0
0-1
ICE
Continuous force learning on every operation.
0
0-1
1 MOT. ON
S ingle Motor operation. 0= (2)motors ; 1=(1)motor.
0
0-1
OPEN IN OTHER DIRECT.
0 = Pull to open; 1 = Pus h to open
0
0-1
S AFE 1 *
0
0-8
S AFE 2 *
Configuration of s afety input terminal 74. Defaulted as Bar (Safety Edge)
6
0-8
Configuration of command input terminal 61. Defaulted as S tart E
0
0-6
4
0-6
AUX 3 *
0
0-8
FIXED CODE
Rolling code defeat. 0 = rolling code; 1 = fixed code
0
0-1
Quick remote programming. 0 = dis abled; 1 = enabled
1
0-1
S ERIAL MODE
0 = Slave unit; 1 = Mas ter unit
0
0-1
ADDRES S
Unit's network identification number.
0
0-127
Configuration of Expans ion board input 1. Defaulted as S tart command.
1
0-14
Configuration of Expans ion board input 2. Defaulted as S tart command.
0
0-10
EXPO 1 *
Configuration of Expans ion board output 1. Defaulted as Traffic light control..
9
0-9
EXPO 2 *
Configuration of Expans ion board output 2. Defaulted as Traffic light control..
9
0-9
Red light flas hes for 3 s ec. at every s tart. 0 = Off; 1 = On
0
0-1
TRAFFIC LIGHT RED LAMP ALWAYS ON
Red light remains on when gate is clos ed. 0 = Off; 1 = On
0
0-1
RADIO >
ADD S TART
Learns trans mitter button as S TART command
ADD 2CH
ERASE 64
Eras e complete memory
COD RX
S how receiver ID Code
WK
W LINK.
DEFAULT
Res tores board to factory s ettings . No effect on RADIO
LANGUAGE >
Italian
French
German
ENG
Englis h
ESP
S panis h
AUTOS ET
Operates motor(s ) s everal times and automatically adjus t its FORCE s ettings
L. S W ADJ
Limit of travel adjus tment. Only available with type 4 and 5 motors
S TAT >
Dis plays board firmware vers ion.
N. CYCLES
Dis plays number of hundreds of cycles (001=100; 010=1000; 100=10,000)
N. REMOTES
Dis plays the number of remotes in memory.
ERR
Dis plays the las t 30 board errors in des cending order.
PASS WORD
Pas s word s etting for wireles s programmer
CLS DELAY TIME
TRF. LGHT.CLR. T
OP. DIS T. S LOWD
CL. DIS T. SLOWD
DIS T. DECEL
CLS . FORCE
FAS T CLS.
PRE-ALARM
IBL OPEN
IBL TCA
IBL CLOS E
PRES S SWC
Configuration of s afety input terminal 72. Defaulted as Phot (Obs truction)
IC 1 *
IC 2 *
Configuration of command input terminal 62. Defaulted as Ped (Partial open)
Configuration of auxiliary output terminals 26 & 27. Defaulted as 2
nd
channel contacts .
RADIO PROG
EXPI 1 *
EXPI 2 *
TRAFFIC LIGHT PREFLAS HING
Learns trans mitter button as 2
nd
channel
ITA
FRA
DEU
VERS
23
see page 20
see page 21