background image

AUX3

 max contact rating: 24v, 3W

(transistor output)

AUXILIARY OUTPUTS

The Thalia board has two auxiliary outputs. The first (20 & 21), is 
a 24 volt, courtesy light output that will activate upon activation 
of the gate, and will remain on for 90 seconds after the gate has 
closed.
The second output labeled 

AUX 3 

(26 & 27), is defaulted as 

second channel radio receiver output, but can be re-
programmed to perform any of the following functions under the 

LOGIC

 sub-menu:

20

21

26

27

20

 & 

21

 – 

24

 VO

LT

 CO

UR

TE

SY

LIG

HT

 OU

TP

UT

 (2

5W

 M

AX

)

26

 & 

27

 – 

AU

X 3

N.

O. 

CO

NT

AC

T

RELAY COMMON

RELAY N.C.

POWER 24V +

POWER 24V -

PROGRAMMING: LOGIC > SAFE 2 > 004 (PHOT CL)

AUX3 > 006

Shadow loop detector

EXAMPLE

: SHADOW

 LOOP DETECTOR WIRING

USING AUXILIARY OUTPUT

VALUE

FUNCTION

0
1
2
3
4
5
6
7
8

2ND CHANNEL RECEIVER OUTPUT. Output active when transmitter activates the 2nd channel
GATE OPEN LIGHT. Output active when gate is not closed. flashes while closing
COURTESY LIGHT. Output active during and for 90 seconds after operation.
GATE NOT CLOSED. Output active until close limit is reached
START OF CYCLE. Output active for 1 second at the beginning of each cycle
GATE OPEN ALARM. Output active if gate is held open for more than double the timer to close time
GATE RUNNING. Output active while motors are powered
SOLENOID LOCK. Output active for 2 second at the beginning of open cycle
MAGNETIC LOCK. Output active when gate is closed

21

Summary of Contents for PHOBOS NL BT

Page 1: ...installation manual version 130308 Phobos N L BT Thalia control board tuned to you Professional installation required welding might be needed ...

Page 2: ...pplied for exposed rollers 2 The operator is intended for installation only on gates used for vehicles Pedestrians must be supplied with a separate access opening The pedestrian access opening shall be designed to promote pedestrian usage Locate the gate such that persons will not come in contact with the vehicular gate during the entire path of travel of the vehicular gate 3 The gate must be inst...

Page 3: ... leaf both to close and to open it CONTROL There are various options when it comes to the control system manual remote control access control with magnetic badge etc depending on the installation s needs and characteristics See the relevant instructions for the various control system options People due to use the automated device must be instructed how to control and use it OPERATIONAL SAFETY The ...

Page 4: ...e Standard Control Box 12 Installing the Optional Control Box 13 Motor Connections 14 Quick Setup Menu 15 Presets 17 Accessory Connections 19 Accessory Power Command Inputs Safety Devices 20 Safety Loop Detector Wiring Auxiliary Outputs 21 Shadow Loop Detector Wiring Navigating the Main Menu 22 Programming Menu 23 Other Accessories Connections 24 Magnetic Lock Wiring Battery Backup Wiring Maintena...

Page 5: ... technician The product warranty may be voided if installed or serviced by a unqualified person an external locking mechanism is suggested for gates over 10 feet long 5 WARNING Please read and follow all instructions before installing and operating this product Follow all local and federal building and electrical BFT is not responsible for faults or damage cause by improper installation applicatio...

Page 6: ...post hinge offset Hinge offset Distance between the center line of the hinge and the inside edge of the gate post The black dots represent the recommended bolt placement must be between 7 7 1 2 Post bracket length position 1 2 3 4 Hinge offset 1 1 8 min up to 1 5 8 up to 1 7 8 up to 2 1 4 up to 2 5 8 7 1 2 is best 7 1 2 is best The suggested post bracket length positions are accurate only if the g...

Page 7: ...the post bracket to the hinge center line If you feel that you have followed the instructions on how to mount the brackets and the distance of the hole of the gate bracket to the hinge center line is greater than that of the post bracket stop the installation process and contact technical support hinge center line post bracket line hinge center line post bracket line gate bracket post bracket gate...

Page 8: ...ions are not standard installations The post bracket should require modifications and or welding The following illustrations do not represent the actual assembly of the post bracket Its intentions is to illustrate the directions and dimensions of the bracket in relationship to the gate With the gate opened 90 the distance between the mounting hole in both brackets must be 27 inches OUTSIDE INSIDE ...

Page 9: ... Install the o ring over the cable so that it is about 1 2 from the edge of the outer jacket 2 Turn the actuator upside down Connect the white wire to terminal 1 the red wire to terminal 2 and the black wire to terminal 3 3 Install the back cover making sure that the o ring fits inside the groove to seal the operator from moisture 9 ...

Page 10: ...a secure location Install the snap rings only once you have completely finalized the installation and all adjustments lock nut pivot bolt spacer collar flat washer snap ring flat washer snap ring MOUNTING THE ACTUATOR MAKE SURE THAT THE BODY OF THE ACTUATOR DOES NOT HIT THE MOUNTING BRACKET WHEN THE GATE IS FULLY CLOSED 10 ...

Page 11: ... 3 SET THE OPEN LIMIT Push the gate to its fully open position Remove the screw that holds the proximity sensor closest to the actuator body Slide it forward so that the back end of the sensor housing is 3 1 2 from the center of the drive carriage and re attach screw that secures sensor in place 3 1 2 4 RE ENGAGE THE MANUAL RELEASE Use triangular key and turn counterclockwise to re engage gears SE...

Page 12: ... components Use plastic anchors for best results Mounting the enclosure 12 OK 10 11 14 15 20 21 26 27 40 41 42 43 44 45 50 51 52 60 61 62 70 71 72 73 74 75 10 11 14 15 20 21 26 27 120 Volts Line Neutral 120 Volts single phase power is connected to the terminal strip on the lower left corner of the control board as shown Max power draw 1 5 Amps Federal and local electrical codes must be followed Co...

Page 13: ...o not drill through the interior of the enclosure Bring all your wiring and or conduits through the bottom of the enclosure For best results use a step drill bit to perforate the enclosure to the needed size opening Do not perforate the top of the enclosure INSTALLING THE OPTIONAL CONTROL BOX 13 Mounting the enclosure Connecting power ...

Page 14: ... gate system connect the motor wires from the gate that When installing a two leaf gate system connect the motor wires from the gate that needs to needs to open first open first to Motor 1 connections 10 11 42 and connect the motor to Motor 1 connections 10 11 42 and connect the motor wires from the gate that needs to wires from the gate that needs to close first close first to Motor 2 connections...

Page 15: ...up Menu flow chart Quick Setup Menu navigation Pressing the button scrolls UP Pressing the button scrolls DOWN Pressing the OK button moves to the NEXT selection Pressing and at the same time EXITS the menu QUICK SETUP MENU OK STEP 1 Enter Quick Setup Menu OK OK STEP 2 Set the menu language Press the OK button once the display will immediately read lang language followed by ita italian OK scroll d...

Page 16: ...he button STEP 3 Select the type of operator OK and then press ok to select STEP 5 Set the opening direction OK dir direction will be displayed for a second followed by int interior OK select int if the gates open in or OK press and select ext exterior if the gates open out QUICK SETUP MENU STEP 6 Set the desired preset OK preset will be displayed OK followed by ar use the button to scroll down an...

Page 17: ...START input is ignored during the open cycle Instant Reverse On Closing A START command will instantly re open gates during the close cycle Otherwise a START command first stops the gate requiring a second command to re open Hold To Run START command is disabled Gate requires a constant open or close command for it to run Quick Remote Programming Allows adding remotes wirelessly using an existing ...

Page 18: ...op buttons on your mitto remote when the screen reads release release the two buttons OK OK after selecting your preset the screen will display prog programming for a few seconds the screen will the display autoset be aware that the gate will run at full torque during the process press ok when ready STEP 7 Run the AUTOSET make sure that the path of the gate is clear of traffic and obstructions OK ...

Page 19: ...losing loop detectors Pedestrian opening Partially opens Motor 1 only TIMER Hold Open input Holds partially open motor 1 PED TIMER PED Command inputs 1 and 2 can be re programmed to perform any of the following functions ACCESSORY POWER ACCESSORY CONNECTIONS Please refer to LOGIC programming for IC 1 and IC 2 re programming COMMAND INPUTS PROGRAMMING LOGIC IC 000 006 50 51 52 5 0 2 4 V A c c e s s...

Page 20: ...ble with the terminal numbers and its corresponding functions and default values Both SAFE1 and SAFE2 can be programmed to perform any of the following functions under the LOGIC sub menu RELAY COMMON RELAY N C POWER 24V POWER 24V EXAMPLE SAFETY LOOP DETECTOR OR SAFETY PHOTO BEAM SENSOR WIRING VALUE FUNCTION DESCRIPTION 000 System reacts to the input in both opening stops and closing reverses cycle...

Page 21: ...OWER 24V PROGRAMMING LOGIC SAFE 2 004 PHOT CL AUX3 006 Shadow loop detector EXAMPLE SHADOW LOOP DETECTOR WIRING USING AUXILIARY OUTPUT VALUE FUNCTION 0 1 2 3 4 5 6 7 8 2ND CHANNEL RECEIVER OUTPUT Output active when transmitter activates the 2nd channel GATE OPEN LIGHT Output active when gate is not closed flashes while closing COURTESY LIGHT Output active during and for 90 seconds after operation ...

Page 22: ...g LANGUAGE Selection of menu language AUTOSET Motor learn feature STAT Provides firmware and memory information PASSWORD Password setting for wireless programmer Main Programming Menu navigation Pressing the button scrolls up or increases value Pressing the button scrolls down or decreases value Pressing the OK button serves as ENTER Pressing and at the same time serves as BACK OK UP DOWN ENTER BA...

Page 23: ...rs 1 1 motor 0 0 1 OPEN IN OTHER DIRECT 0 Pull to open 1 Push to open 0 0 1 SAFE 1 0 0 8 SAFE 2 Configuration of safety input terminal 74 Defaulted as Bar Safety Edge 6 0 8 Configuration of command input terminal 61 Defaulted as Start E 0 0 6 4 0 6 AUX 3 0 0 8 FIXED CODE Rolling code defeat 0 rolling code 1 fixed code 0 0 1 Quick remote programming 0 disabled 1 enabled 1 0 1 SERIAL MODE 0 Slave un...

Page 24: ... LOCK WIRING USING BFT 24V AC DC RELAY OTHER ACCESSORIES CONNECTIONS 4 5 3 Transformer Power plug YELLOW normally closed contact BLUE common RED 24V WHITE 24V Dedicated power supply BATTERY BACKUP WIRING DIAGRAM 20 2 1 P N KRELAY24V SBS battery backup board 12v batteries GY BK 24 1 2 3 4 5 ...

Page 25: ...gear by using the triangular key and turning clockwise Re engage the gears by turning the key counterclockwise 25 ERROR DESCRIPTION ERROR DESCRIPTION ER20 MOTOR 2 IMPROPER ENCODER MOVEMENT DETECTED ER35 MOTOR 1 OBSTACLE DETECTION DURING OPENING ER22 MOTOR 2 OPPOSITE MOVEMENT ER36 MOTOR 1 OBSTACLE DETECTION DURING CLOSING ER25 MOTOR 1 IMPROPER ENCODER MOVEMENT DETECTED ER37 MOTOR 1 OBSTACLE DETECTI...

Page 26: ... fuse 2 5 Amps slow blow 5mm x 20mm Secondary fuse 3 15 Amps slow blow 5mm x 20mm It is highly recommended to when necessary replace both the limit sensors and motor board together Thalia control board Includes enclosure and transformer P N D113745 00001 Phobos motor board P N D111709 00001 26 Gate Bracket Magnet Holder P N N999427 End Cap P N I105800 ...

Page 27: ...th memory for 128 or 2048 transmitters optional it is capable of controlling two independent gates or doors Programmable relays can also be used as hold open feature AEL 433 P N D113632 External antenna tuned for 433Mhz doubles the standard range of the remote controls MITTO P N D111904 2 buttons P N D111906 4 buttons Extended range 200 ft under optimal conditions two button remote control Can be ...

Page 28: ...ART Cycles between open stop and close Normally used with single push buttons and radio receivers OPEN Open only command Used with open buttons free exit and or open only devices CLOSE Close only Used with close buttons and closing loop detectors Pedestrian opening Partially opens Motor 1 only TIMER Hold Open input Holds partially open motor 1 PED TIMER PED 001 002 003 004 005 006 IC Values termin...

Reviews: