448
D811230_04
TRIMMER T2 BRAKE
: Controls the braking couple.
ATTENTION -
The trimmer braking effect is set by the manufacturer during
testing and is then sealed. If the trimmer needs recalibrating, please take
note of the following:
a) Braking should not be sudden.
b) Braking which is too weak creates slippage due to inertia.
Braking can be increased by turning it clockwise.
7) LED FUNCTIONS
(Fig.1)
7.1) BOARD ORION G
1 - START
Lights up upon start impulse.
2 - STOP
Turns off upon opening of the block contact.
3 - PHOTOCELL
Turns off if photoelectric cells are not aligned or if there are obstacles
interfering with the cells.
4 - OPENING LIMIT SWITCH
Turns off in a full open position.
5 - CLOSING LIMIT SWITCH
Turns off in a full closed position.
6 - OPENS
Turns on during the motor opening phase.
7 - CLOSES
Turns on during the motor closing phase.
8 - MAINS SUPPLY
Turns on when there is power and when the fuses are integral.
SOG optional board
9 - OPENS
Turns on at the
“
hold-to-run
”
open command.
10 - CLOSES
Turns on at the
“
hold-to-run
”
close command.
11 - RUBBER SKIRT ALARM
Turns on when the rubber or infrared safety skirts is activated.
12 - PEDESTRIAN
Turns on at the pedestrian opening command.
8) MAINTENANCE AND DEMOLITION
The maintenance of the system should only be carried out by qualified
personnel regularly.
The materials making up the set and its packing must
be disposed of according to the regulations in force.
Batteries must be
properly disposed of.
The descriptions and illustrations contained in the present manual
are not binding. The Company reserves the right to make any alterations
deemed appropriate for the technical, manufacturing and commercial
improvement of the product, while leaving the essential product
features unchanged, at any time and without undertaking to update
the present publication.
ORION G-GBR
ORION G-GBR
CONTROL UNITS
CONTROL UNITS