~5 mm
A
B
FC2
(CLOSE)
~5 mm
FC1
(OPEN)
OPENING LIMIT SWITCH ADJUSTMENT
Open the gate�
As the last operation:
block the gate�
Unscrew the FC1 cam screw
Screw the FC1 cam screw in�
CLOSING LIMIT SWITCH ADJUSTMENT
Close the gate�
Unscrew the FC2 cam screw
Screw the FC2 cam screw in�
WARNING!
To prevent the limit
switch wire from breaking, fix
screw A keeping wire B taut�
Move the cam to 5 mm from
the edge of the bracket
Move the cam to 5 mm from
the edge of the bracket
Repeat the same operations for the other leaf!
Unlock the operator as shown
and
OPEN the leaf ad far as
required :