CONNECTING TO THE MAINS POWER SUPPLY
- Before connecting the power supply, make sure the product's ratings match the mains ratings and that a suitable
residual current circuit breaker and overcurrent protection device have been installed upstream from the electrical
system� Install an omnipolar switch or circuit breaker on the mains power line that permits full cut-off in overvoltage
III category conditions�
- Make sure that upstream from the mains power supply there is a residual current circuit breaker that is triggered at
no more than 0�03A and complies with the provisions in force�
- Make sure the earth system has been correctly installed: earth all the metal parts belonging to the entry system
(doors, gates, etc�) and all parts of the system featuring an earth terminal�
For connection to the mains power supply, use a multicore cable with a cross-sectional area of at least 3x1�5mm
2
(by
way of example, a type H05 VV-F cable can be used with a cross-sectional area of 3x1�5mm
2
)� To connect auxiliary
equipment, use wires with a cross-sectional area of at least 0�5 mm
2
�
- Wires must be secured with additional fastening near the terminals (for example, using cable clamps) in order to
keep live parts well separated from safety extra low voltage parts�
FABER BT - FABER L BT KIT
-
47
D812458 10550_01
Summary of Contents for FABER BT
Page 7: ...ATTREZZI NECESSARI FABER BT FABER L BT KIT 7 D812458 10550_01 ...
Page 36: ...NECESSARY TOOLS 36 FABER BT FABER L BT KIT D812458 10550_01 ...
Page 65: ...OUTILS NÉCESSAIRES FABER BT FABER L BT KIT 65 D812458 10550_01 ...
Page 94: ...ERFORDERLICHES WERKZEUG 94 FABER BT FABER L BT KIT D812458 10550_01 ...
Page 118: ...118 FABER BT FABER L BT KIT D812458 10550_01 ...
Page 119: ...FABER BT FABER L BT KIT 119 D812458 10550_01 ...