background image

INSTALLATION MANUAL

ENGLISH

WARNING:  the  anti-tear  rubber  element  must  never  be  completely 
compressed.  Scrupulously  check  that  the  rubber  does  not  become 
totally compressed during operation.

6) ELECTRICAL INSTALLATION SET-UP (Fig.16)
M)

   Actuator

Ft)

   Transmitter photocell

Fr)

   Receiver photocells

T)

    1-2-4 channel transmitter.

Arrange for the connections of accessories and safety and control devices 
to  reach  the  motor  unit,  keeping  the  mains  voltage  connections  clearly 
separate from the extra low safety voltage connections (24V) by means of 
the appropriate cable holder (fig. 8 ref. 5P1).
Proceed to connection following the indications given in the wiring diagram. 
The cables for connecting the accessories must be protected by a raceway 
(fig. 8 ref. 5C1).

7) VENERE Control panel (Fig.17)

Supply to accessories: ..................................................24V~ (180mA max)
.............................................................24V~ Vsafe VENERE (180mA max)
Torque limiter setting:..............................................on closing and opening
Automatic closing time:.........................................................from 3 to 120s
Blinker connection:..............................................................24V~ max 25W
Service light switching-on time:..............................................................90s
Incorporated rolling-code radio receiver:..................frequency 433.92 MHz
Coding:.......................................................................rolling-code algorithm
No. combinations:...........................................................................4 milliard
Antenna impedance:............................................................50Ohm (RG58)
Max no. radio controls to be memorised:..................................................10
Slow-down distance:................closing: ~24 cm ............... opening: ~24 cm
Fuses:......................................................................................see figure 17  

7.1) Terminal board connections (Fig.17)
WARNINGS - For wiring and installation operations, refer to the current 
standards and good technical principles. 

The wires supplied with extra low safety voltage (24V) must be kept physi-
cally separate from the low voltage wires, or else they must be provided with 
adequate additional insulation of at least 1mm.
The  wires  must  be  clamped  by  an  extra  fastener  near  the  terminals,  for 
example by bands.

TERMINAL

DESCRIPTION

JP6

transformer wiring

JP7

motor wiring

1-2

Antenna input for integrated radio-receiver board
(1: 

BRAID

. 2: 

SIGNAL

)

3-4

START input (N.O.)

 

3-5

STOP input (N.C.) If not used, leave the jumper inserted.

3-6

PHOTOCELL input (N.C.) If not used, leave the jumper 
inserted.

3-7

FAULT input (N.O.)
Input for photocells provided with checking N.O. contact

8-9

24 V~ output for blinking light (25 W max)

10-11

24V~ 180mA max output – power supply for photocells 
or other devices

12-13

24V~ Vsafe 180mA max output – power supply for checking 
photocell transmitters.

7.2) LED (Fig.17)       

 

The led functions are as follows:

“RADIO”:

Incorporated radio-receiver led. 

“SET”:

  Limit device setting led - power ON.

7.3) DIP-SWITCH SELECTION (Fig.17)
DIP1) IBL

 – Locks impulses.

ON:  During the opening phase, does not accept START commands.
OFF:  During the opening phase, accepts START commands.

DIP2) TEST PHOT

ON:  Enables  photocell  checking  (5-connector  photocells  must  be  used  

- see Fig.17A-). 

OFF:  Disables photocell checking.

7.4) TRIMMER SETTING (Fig.17)
TCA

Sets the automatic closing time, after which the gate closes automatically 

(can be set from 3 to 120 sec). If the trimmer is turned all the way, the TCA 
is disabled.

OPENING TORQUE

Sets the ampere-stop sensitivity on opening.

CLOSING TORQUE

Sets the ampere-stop sensitivity on closing.

NOTE: In case of obstacle detection, the Ampere-stop function halts 

the  leaf  movement,  reverses  the  motion  for  1  sec.  and  stays  in  the 

STOP state.

WARNING:  check  that  the  impact  force  value  measured  at  the 

points established by the EN 12445 standard is lower than that 

specified in the EN 12453 standard.

Incorrect sensitivity setting can cause injuries to persons or ani-

mals, or damage to things.

7.5) BUTTONS

“UP”:    

limit device setting and opening command. An autoset operation 
of the  torque will be performed by keeping this button pressed 
for 5 seconds (Fig.19).

“DOWN”:

 limit device setting and closing command. 

“OK”:

   radio programming.

 

 

 

8) LIMIT DEVICE SETTING (Fig.18)

1)  Simultaneously  press  the “UP”  and “DOWN”  keys  for  5  seconds. The 

“SET” led blinks to indicate that the limit device setting is activated.

2)  Bring the leaf to the required closing position, using the “UP” and “DOWN” 

buttons on the control unit, and keeping in mind that the “DOWN” button 
closes the leaf, while the “UP” button opens the leaf.

3)  As soon as the leaf reaches the required closing position, press the “OK” 

button in order to memorise the limit device closing position. The “SET” 
led confirms data storage by blinking for 1 second.

4)  Bring the leaf to the required opening position, using the “UP” and “DOWN” 

buttons on the control unit, and keeping in mind that the “DOWN” button 
closes the leaf, while the “UP” button opens the leaf.

5)  As soon as the leaf reaches the required opening position, press the 

“OK” button in order to memorise the limit device opening position. The 
“SET” led confirms data storage by blinking for 1 second and then lits up 
again. 

6)  Correctly position the “carriage lock” against the carriage (fig.18 ref.6 A-B).

NOTE 1: 

These manoeuvres are carried out in “hold-to-run” mode at reduced 

speed and with no safety devices activated.

NOTE 2: 

In case of errors, the “SET” led remains off on for 5 seconds.

9) OPENING / CLOSING TORQUE AUTOSETTING (Fig.19)

1)  After reaching the closing end-of-stroke position, press the “UP” button 

for 5 seconds.

2)  The “SET” led  blinks rapidly and the leaf starts to open until it reaches 

the opening end-of-stroke.

3)  3 second down time.
4)  The “SET” led blinks rapidly and the leaf starts to close until it reaches 

the closing end-of-stroke

5)  After completing the autoset adjust the opening/closing torque trimmers 

so as to obtain the desired sensitivity to the obstacle.

Any input activation (START, RADIO TRANSMITTER, STOP, PHOTOCELL) 

during autosetting will annul the autoset in progress.

10) INTEGRATED RECEIVER

Transmitter versions which can be used:

all Rolling Code transmitters compatible with 

.

10.1)ANTENNA INSTALLATION
Use an antenna tuned to 433MHz.
For Antenna-Receiver connection, use RG8 coaxial cable.

The presence of metallic masses next to the antenna can interfere with radio 
reception. In case of insufficient transmitter range, move the antenna to a 
more suitable position.

10.2) MANUAL TRANSMITTER PROGRAMMING (Fig.20)

1)  Press the “OK” button on the control unit.
2)  When the “RADIO” LED blinks, press the transmitter P1 hidden key, and 

the “RADIO” LED will stay on permanently.

3)  Press the key to be memorised on the transmitter, LED “RADIO” will start  

blinking again.

4)  To memorise another transmitter, repeat steps 2) and 3).
5)  To exit the storage mode, wait until the LED is switched off completely.

 

BOTTICELLI VENERE - 

1

D81

1492_02

Summary of Contents for BOTTICELLI

Page 1: ...I Tel naz 0445 696511 Tel int 39 0445 696533 Fax 0445 696522 Internet www bft it E mail sales bft it BOTTICELLI VENERE 8 027908 288127 AUTOMAZIONI PER PORTE BASCULANTI E SEZIONALI AUTOMATION FOR OVERHEAD AND SECTIONAL GARAGE DOORS AUTOMATION POUR PORTES BASCULANTES ET SECTIONALES GARAGENTORANTRIEB FÜR SCHWING UND SEKTIONALTORE AUTOMATIZACIONES PARA PUERTAS BASCULANTE Y SECCIONALES AUTOMATIZAÇÕES P...

Page 2: ... BOTTICELLI VENERE D811492_02 ...

Page 3: ...ut of children s reach in order to avoid any unintentional automation activation Do not intentionally oppose the leaf movement Do not attempt to open the door manually if the internal locking system has not been released by pulling the appropriate wire connected to the carriage fig 1 or the external lock SM1 or SET S fig 2 fig 3 activated Do not modify the automation components In case of malfunct...

Page 4: ... by the EN 12978 Standard Fit any fixed control within sight of the door but away from moving parts higher than 1 5 m Add a label bearing the following notices Keep children away from the moving door WARNING risk of squashing Regularlycheckthatthedoorreversesitsmovementwhencollidingwithan obstacle 50 mm away from the floor and if necessary set it correctly 2 GENERAL OUTLINE The BOTTICELLI system i...

Page 5: ...n halts the leaf movement reverses the motion for 1 sec and stays in the STOP state WARNING check that the impact force value measured at the points established by the EN 12445 standard is lower than that specified in the EN 12453 standard Incorrect sensitivity setting can cause injuries to persons or ani mals or damage to things 7 5 BUTTONS UP limit device setting and opening command An autoset o...

Page 6: ...ntrols manual radio control magnetic card access etc depending on the installation requirements and characteristics For the various control systems see the relevant instructions The automation device users must be instructed on control and operation 15 ACCESSORIES SM1 External release device to be applied to the cremone bolt already fitted to the overhead door fig 22 SET S External release device ...

Page 7: ...146 253 16 65 378 35 3380 2780 3760 3160 1 2 250 E14 24V 25W max BOTTICELLI VENERE 27 D811492_02 ...

Page 8: ...28 BOTTICELLI VENERE D811492_02 ...

Page 9: ...BOTTICELLI VENERE 29 D811492_02 ...

Page 10: ...ELD JP6 JP7 Luce di cortesia Courtesy lamp Lampe de courtoisie Hilfsbeleuchtung Luz interior lâmpada de cortesia Fusibile Fuse Fusible Schmelzsicherung Fusible Fusível Fig 26 1 25 AT Trimmer regolazioni Adjustment trimmer Trimmer réglages Einstelltrimmer Trimmers para las regulaciones trimmer regulações DIP SWITCH M Fr Ft T 17 UP DOWN Fig 17A 3 6 7 10 11 12 13 3 6 7 10 11 12 13 DIP TEST PHOT ON DI...

Page 11: ...PO DE FIN DE CARRERA REGULAÇÃO DO FIM DE CURSO AUTOSET COPPIA APERTURA CHIUSURA OPENING CLOSING TORQUE AUTOSETTING RÉGLAGE AUTOMATIQUE COUPLE OUVERTURE FERMETURE AUTOSET DREHMOMENT ÖFFNUNG SCHLIESSUNG AJUSTE AUTOMATICO DEL PAR EN FASE DE APERTURA CIERRE AUTOSET BINÁRIO DE ABERTURA FECHO CHIUSURA CLOSING FERMETURE SCHLIESSUNG CIERRE FECHO APERTURA OPENING OUVERTURE ÖFFNUNG APERTURA ABERTURA SET 6 B...

Page 12: ...ransmitter to memorise Radiocommande à mémoriser Zu speichernde Funksteuerung Radiomando que memorizar Radiocomando a memorizar Radiocomando da memorizzare Radio transmitter to memorise Radiocommande à mémoriser Zu speichernde Funksteuerung Radiomando que memorizar Radiocomando a memorizar Fig 21 Fig 22 Fig 23 Fig 24 Fig 25 10 sec PROGRAMMAZIONE TRASMETTITORI MANUALE MANUAL TRANSMITTER PROGRAMMING...

Page 13: ...RTA CERRADA PORTA FECHADA Montaggio tappi per operatore BOTTICELLI Assembly of caps for BOTTICELLI operator Montage bouchons pour opérateur BOTTICELLI Montage der Stopfen für Antrieb BOTTICELLI Montajie topones para automatisacio n BOTTICELLI Montagem de tampões para operador BOTTICELLI BOTTICELLI VENERE 33 D811492_02 ...

Page 14: ......

Reviews: