INSTALLATION MANUAL
2) GENERAL INFORMATION
Actuator for motorizing residential and industrial sectional doors.
Its compact design and mounting versatility mean the drive can be applied in
different ways.
3) TECHNICAL SPECIFICATIONS
Power supply:
220-230V 50/60Hz (*)
Max. power input:
240W
Limit switch:
Electronic ENCODER model
Output shaft MAX. 18 rpm
Operating temperature range:
-15°C / +55°C
Max. door size:
ARGO: 20 m
2
ARGO G: 35 m
2
Max. torque:
ARGO: 55 Nm
ARGO G: 80 Nm
Max output rpm:
ARGO: 30 min
-1
ARGO G: 18 min
-1
Lubrication:
Lifetime greased
Manual operation:
Knob-operated mechanical release
Protection rating:
IP 40
Sound pressure:
<70dbA
Operator weight:
10 kg
Dimensions:
See Fig. H
Accessories power supply:
24V~ (180 mA)
Flashing light connection:
24V max 25W
Fuses:
See Fig. D
Built-in Rolling-Code radio-receiver:
frequency 433.92MHz
(*) Special supply voltages to order.
Usable transmitter versions:
All ROLLING CODE transmitters compatible with
.
4) REMOVING THE COVER Fig. A
5) TUBE ARRANGEMENT Fig. B
6) INSTALLING THE OPERATOR Fig. C
7) CABLE ENTRY FIG. I
8) MANUAL RELEASE (
See USER GUIDE
-FIG. 1-).
----------------------------------------------------------
9) WIRING
TERMINAL DESCRIPTION
JP2
Transformer wiring
JP10
Motor wiring
1-2
Antenna input for built-in radio-receiver board (1:BRAIDING 2: SIGNAL)
3-4
START/OPEN INPUT (N.O.)
3-5
STOP input (N.C.) If not used, leave jumper inserted
3-6
PHOTOCELL input (N.C.) If not used, leave jumper inserted
3-7
SAFETY EDGE input (N.C.) If not used, leave jumper inserted
8-9
24 V~ output for flashing light (max. 25 W)
10-11
24V~ max. 180mA output - power supply to photocells or other devices.
12-13
24V~ Vsafe max. 180mA output - power supply to transmitters
photocells with test.
14-15
(NO contact) / Output 1 height programmable
16-17
PARTIAL OPENING/CLOSE input (N.O.)
1-2 (SCS-IO)
PHOT-FAULT input (NO). Input for photocells equipped with NO test contact.
1-3 (SCS-IO)
BAR-FAULT input (NO). Input for safety edges equipped with NO
test contact.
4-5 (SCS-IO)
(NO contact) / Output 2 Height programmable
6-7 (SCS-IO)
Gate open light/2nd radio channel output (NO contact)
9.1) SAFETY DEVICES
When using the SCS-IO board with the photocell test feature, the Fault must
be connected.
Note: only use receiving safety devices with free changeover contact.
1-A:
Connection of 1 untested device (photocell or safety edge).
Fig. L2-B: Connection of 1 tested device (photocell or safety edge).
Fig. L3-C: Connection of 2 tested devices (photocells or safety edges). This con-
nection is made possible via the SCS-IO optional module only.
10) ADJUSTMENTS
RECOMMENDED ADJUSTMENT SEQUENCE:
Adjusting the limit switches (Fig. E)
Autoset (Fig. F)
Programming remote controls (Fig. G)
Setting of parameters/logic, where necessary
10.1) PARAMETERS MENU (
param
)
(TABLE “A” PARAMETERS)
10.2) LOGIC MENU (
logic
)
(TABLE “B” LOGIC)
10.3) RADIO MENU (
RADIO
)
Logic
Description
add start
Add Start Key
associates the desired key with the Start command
add 2ch
Add 2ch Key
associates the desired key with the 2nd radio channel command
read
Read
Checks a key of a receiver and, if memorized, returns the
number of the receiver in the memory location (from 01 to
64) and number of the key (T1-T2-T3 or T4).
erase 64
Erase List
WARNING!
Erases all memorized remote controls from
the receiver’s memory.
cod RX
Read receiver code
Displays receiver code required for cloning remote controls.
uk
ON =
Enables remote programming of cards via a previously me-
morized W LINK transmitter. It remains enabled for 3 minutes
from the time the W LINK remote control is last pressed.
OFF=
W LINK programming disabled.
- IMPORTANT NOTE: THE FIRST TRANSMITTER MEMORIZED MUST BE
IDENTIFIED BY ATTACHING THE KEY LABEL (MASTER).
In the event of manual programming, the first transmitter assigns the RECEIVER’S
KEY CODE: this code is required to subsequently clone the radio transmitters.
The Clonix built-in on-board receiver also has a number of important advanced
features:
• Cloning of master transmitter (rolling code or fixed code)
• Cloning to replace transmitters already entered in receiver
• Transmitter database management
• Receiver community management
To use these advanced features, refer to the universal handheld programmer’s
instructions and to the CLONIX Programming Guide, which come with the uni-
versal handheld programmer device.
10.4) LANGUAGE MENU (
language
)
Used to set the programmer’s language on the display.
10.5) DEFAULT MENU (
default
)
Restores the controller’s default factory settings.
10.6) AUTOSET MENU (
Autoset
)
(Fig. F)
• Move the door to the closed position.
• Launch an autoset operation by going to the relevant menu on the VENERE
D panel.
• As soon as you press the OK button, the “.... .... ....” message is displayed and
the control unit commands the door to perform a full cycle (opening followed
by closing), during which the minimum torque value required for the door to
move is set automatically.
During this stage, it is important to avoid breaking the photocells’ beams and
not to use the START and STOP commands or the display.
Once this operation is complete, the control unit will have automatically set
the optimum torque values. Check them and, where necessary, edit them as
described in the programming section.
WARNING: Check that the force of impact measured at the points
provided for by standard EN 12445 is lower than the value laid down
by standard EN 12453.
Warning!! While the autoset function is running, the obstacle detection
function is not active. Consequently, the installer must monitor the
26 -
ARGO-ARGO G
D814001 00100_01