INSTALLATION MANUAL
13.2) TABLE “B” - LOGIC MENU - (
logic
)
Logic
Default Definition
Cross out
setting
used
Description
TCA
OFF
Automatic Closing
Time
ON
Activates automatic closing
OFF
Excludes automatic closing
Ibl open
OFF
Opening Impulse
lock
ON
The Start impulse has no effect during the opening phase.
OFF
The Start impulse becomes effective during the opening phase.
ibl TCA
OFF
Impulse lock TCA
ON
The Start impulse has no effect during the TCA dwell period.
OFF
The Start impulse becomes effective during the TCA dwell period.
3 step
OFF
3 step
ON
Switches to 3-step logic.
A start impulse has the following effects:
3 steps
4 steps
closed
opens
opens
on closing
stop
open
closes
closes
on opening
stop + TCA
stop + TCA
after stop
opens
opens
OFF
Switches to 4-step logic.
preal
OFF
Pre-alarm
ON
The flashing light comes on approx. 3 seconds before the motors start.
OFF
The flashing light comes on at the same time as the motors start.
hold to run
OFF
Deadman
ON
Hold-to-run operation: the manoeuvre continues as long as the OPEN and CLOSE
control keys are kept pressed. The radio transmitter cannot be used.
OFF
Normal impulse operation.
Photoc. open
OFF
Photocells
during opening
ON
When beam is broken, operation of the photocell is switched off during opening. During closing,
movement is reversed immediately.
OFF
When beam is broken, photocells are active during both opening and closing. When beam is broken
during closing, movement is reversed only once the photocell is cleared.
test phot
OFF
Photocell test
ON
Switches photocell testing on
OFF
Switches photocell testing off
If disabled (OFF), it inhibits the photocell testing function, enabling connection of devices not equipped
with supplementary test contacts.
test bar
OFF
Safety edge
testing
ON
Switches safety edge testing on.
OFF
Switches safety edge testing off
If disabled (OFF), it inhibits the safety edge testing function, enabling connection of devices not equip-
ped with supplementary test contacts.
ster
OFF
Master/slave
ON
Control panel is set up as the Master unit in a centralized serial connection system.
OFF
Control panel is set up as a Slave unit in a centralized serial connection system.
fixed code
OFF
Fixed code
ON
Receiver is configured for operation in fixed-code mode.
OFF
Receiver is configured for operation in rolling-code mode.
radio prog
ON
Remote control
programming
ON
Enables wireless memorizing of transmitters:
1- Press in sequence the hidden key (P1) and normal key (T1-T2-T3-T4) of a transmitter that has already
been memorized in standard mode via the radio menu.
2- Press within 10 secs. the hidden key (P1) and normal key (T1-T2-T3-T4) of a transmitter to be memorized.
IMPORTANT: Enables the automatic addition of new transmitters, clones and replays.
The receiver exits programming mode after 10 secs.: you can use this time to enter other new tran-
smitters. This mode does not require access to the control panel.
OFF
Disables wireless memorizing of transmitters.
Transmitters are memorized only using the relevant Radio menu.
IMPORTANT: Disables the automatic addition of new transmitters, clones and replays.
SCA 2Ch
OFF
Gate open light or
2nd radio channel
ON
The output between terminals 14-15 is set as Gate open light:
in this case, the 2nd radio channel controls pedestrian opening.
OFF
The output between terminals 14-15 is set as 2nd radio channel.
start -
close
OFF
START - CLOSE
setting
ON
Input between terminals 21-22 works as CLOSE.
OFF
Input between terminals 21-22 works as START.
change ot.
OFF
Reversing motion
ON
Change this parameter if the opening direction needs to be changed
OFF
Standard operating mode.
ICE
(special dip 2*)
OFF
ICE
ON
The controller automatically adjusts the Amperostop safety trip threshold. Check that the force of impact
measured at the points provided for by standard EN 12445 is lower than the value laid down by standard
EN 12453. If in doubt, use auxiliary safety devices. This feature is useful when dealing with installations
running at low temperatures.
WARNING: once this feature has been activated, you will need to perform an autoset opening and
closing cycle.
OFF
The Amperostop safety trip threshold stays at the same set value.
*=Refer for universal handheld programmer.
13.3) TABLE C: RADIO MENU (
RADIO
)
Logic
Description
Add start
Add Start Key associates the desired key with the Start command.
add 2ch
Add 2ch Key associates the desired key with the 2nd radio channel command.
erase 64
Erase List WARNING! Erases all memorized remote controls from the receiver’s memory.
Read receiver code Displays receiver code required for cloning remote controls.
ON = Enables remote programming of cards via a previously memorized W LINK transmitter. It remains enabled for 3 minutes from the time the
W LINK remote control is last pressed.
OFF= W LINK programming disabled.
ARES -
23