Transport, Installation and Connection
4-12
Contact-
insert
Crimp contact
inner PUR
jacket
outer shielding
outer PUR
jacket
Plastic insert
thread
union nut
single core
15
20
55
4.8.3
Laying special cable KW6
No contact chamber should be unloaded. All contact
chambers have to be fitted with crimp contacts.
The outer shielding on the CFC-side is clamped extensive
to the housing ground between the plastic insert and the
thread of the gland.
The inner shielding has to be cut off on both ends.