28
MOD. BEZZERA BB012
7 - TROUBLE SHOOTING
Problem
Diagnostics/Solution
Suggestions
The switch light (Fig. 01; pos.
13) does not turn on.
The machine is not powered.
Make sure the plug is correctly
inserted and that the power
cord is not damaged.
The switch light (Fig. 01; pos.
13) is ON but the grinder does
not work.
Thermal protector has cut in.
Wait until the appliance has
cooled down.
The appliance functions cor-
rectly but ground coffee is not
dispensed.
Coffee beans receptacle gate
(Fig. 01; pos. 1) closed.
Push the gate (Fig. 01; pos. 1)
towards the inside to open the
passage of the coffee to the
grinder.
The coffee dispenses insuffi-
ciently, is too cold or coffee de-
posit on the cup bottom.
The coffee dispenses drop by
drop and the quality of the cof-
fee is not good and presents a
dark cream.
Possible causes:
1 - The coffee grind is too fine.
2 - The coffee into the filter
holder is too pressed.
3 - The dose into the filter holder
is excessive.
4 - The grinder mills are worn.
In cases 1-2-3, it is necessary to
adjust the grinder correctly.
In case 4,it is necessary to call a
technician.
The coffee dispenses too
abundantly.
The coffee dispenses too quickly
and the cream is clearer than
usual.
Possible causes:
1 - The grind of the coffee is too
coarse.
2 - The coffee into the filter hold-
er is not pressed enough.
3 - The dose into the filter holder
is excessive.
In cases 1-2-3, it is necessary to
adjust the grinder correctly.