background image

5

8

7

-  During the EMS session or shortly after, redness of the skin may occur at the level of the elec-

trodes (around or below). They usually disappear within two hours of the session. In case of 
persistence of the redness for more than 24h, please consult your doctor. 

- An electrical muscle stimulation (EMS) session can cause muscle pain for some time. 

Reactions

-

fects may occur in the form of :
- Nausea or fainting
- Burns at the location of the electrodes
- Painful sensations, headache
-  Irritation of the skin in the place of the electrodes, even if the gel present on the electrodes 

does not present any known risk of allergic reactions to this day.

3. CHARACTERISTICS

- Pain relief and healing of muscle tension (TENS : 11 preset programmes)
- Strengthening of the muscular mass (EMS : 8 standard programmes)
- Stimulation of the venous return (TENS)
- Easy to use
- Data transfer onto a phone or a Bluetooth 4.0 tablet 

4. USE
4.1 DE

See schema in page 8

SCRIPTION

See schema A page 6

 

2

 Status indicat

 

4

  Micro-USB socket 

of the device

 

5

  Electrodes

-You should stop using the device and should consult with your physician if you experience 
  adverse reactions from the device

The gift box contains the follwing conponents:
Standard Parts:
NO.    Description                                 Quantity
1      BW_TSX                                          1PCS
2      Electrode pad(50*56mm)         2pcs
3      Adaptor                                          1PCS
4      Micro-USB cable                          1PCS
5      Instruction manual                     1PCS

1

  

2

 Status indicator

3

  Removable connector

 

4

  Micro-USB socket 

of the device

 

5

 

 

8

 

 Ele

Battery indicator

 

9

 

Socket for standard USB plug

ctrodes

 

6

  Micro-USB cable

7

 

10

 

 Adaptor

Standard USB plug

11

12

 

Micro-USB plug

Detachable connector

A

B

Year

Month

Day

Serial number

SN

SN:

Serial number

1

3

2

4

12

6

7

8

10

9

5

11

Summary of Contents for Mytens BW-TSX

Page 1: ...ser Manual 072015 1 1 BW TSX 0197 Manufacture Nexmed Technology Co LTD Address 2nd Floor of No 1 building Jia An Technological Industrial Park 67 District Bao An 518101 Shenzhen China BW TSX Web site...

Page 2: ...e in case of anomalies or malfunction Electronic medical equipment requires special precautions regarding electromechanical com patibility It must be installed and used in accord with EMC ElectroMagne...

Page 3: ...s Do not place the electrodes near cancerous lesions because this may have a negative impact on these injuries Do not place the electrodes on skin areas whose sensations are not normal You may burn yo...

Page 4: ...ions Always consult your doctor or midwife if you are pregnant and intend to use the device cal muscle stimulation EMS device could in this case cause a blood clot In case of cognitive impairment If y...

Page 5: ...Strengthening of the muscular mass EMS 8 standard programmes Stimulation of the venous return TENS Easy to use Data transfer onto a phone or a Bluetooth 4 0 tablet 4 USE 4 1 DE See schema in page 8 SC...

Page 6: ...mage do not use the device or one of the electrodes Usable indoors and outdoors the device is not designed to withstand all weather conditions The device is not waterproof Do not wet it and never use...

Page 7: ...angerous However if you experience discomfort it is advisable to decrease the intensity of the programme change or move the electrodes The burst transcuta neous electrical neurostimulation Burst TENS...

Page 8: ...tion must remain comfortable and muscle contractions must not are advised to choose a low intensity to limit muscular fatigue SummaryTable of the EMS Programmes EMS Impulses Treatment site Name Treatm...

Page 9: ...harge the device fully before beginning a session If the charge is not complete at the beginning of a programme the battery may become deplete before the end of the session You cannot use the device w...

Page 10: ...g or biting sensation Note Always connect the device before you place the electrodes on the skin Note Do not place the electrodes on top of each other or so close to each other that they touch each ot...

Page 11: ...ensity lever you want Starting and stopping a treatment Tap the play button on the screen The treatment screen opens and the time starts to count down The status indicator on the device starts to flas...

Page 12: ...en stimulation is uncomfortable i e when you experience an unpleasant stinging or biting sensation Note Always replace the electrodes with electrodes recommended for this device by the manufacturer 5...

Page 13: ...9mmx55 8mm Programmes 19 programmes 11 TENS 8 EMS programmes Battery 3 7V 500mAh Li lon Output voltage max 60mA 10 1000 load Conditions of use 5 C to 40 C with a relative humidity of 15 to 93 atmosph...

Page 14: ...on electromagnetic IMMUNITY The customer or the user of these electrical stimulators should assure that it is used in such environment Immunity test IEC 60601 test level Compliance level Electromagnet...

Page 15: ...ith the legal obligation For transmitters rated at a maximum output power not listed above the recommended separation distance d in meters m can be estimated using the equation applicable to the frequ...

Page 16: ...Pain in the lower back Elbow Pain in the elbow Fore arm Pain in the forearm Wrist Pain in the wrist and carpal tunnel syndrome Hip Pain in the hip 12 Thigh Sciatic pain Knee Knee pain Lower leg Pain...

Page 17: ...ard will not be extended to another per including the user This guarantee covers only the defects of the material or parts occurring during normal use of the pro duct It does not cover the damage caus...

Reviews: