background image

27

28

 10.  SAFETY PRECAUTIONS

 11.  DISPOSAL

IP 22

 C

The first number 2: Protected against solid foreign objects of 12,5 mm Ф and greater. The second
 number: Protected against vertically falling water drops when enclosure titled up to 15º. Vertically 
falling drops shall have no harmful effects when the enclosure is titled at any angle up to 15º

 on either side of the vertical.

aution

Garder au sec / Keep dry

 

Refer to instruction manual. Note on the equipment “Follow instructions for use”.

 

Type BF applied part such as electrode

 

The device, accessories and the packaging have to be disposed correctly at the end of the us-
age. Please follow local ordinances or regulations for disposal.

 

 Manufacturer

SN

 Serial number

This symbol means that this device emits nonionising radiation. All devices and systems 
that include RF transmitters or that intentionally apply RF electromagnetic energy must be 
labelled withthis symbol.

Obsolete batteries must be disposed of in a specially labeled collection container, at toxic 
waste collection points or through an electrical retailer.
You are under legal obligation to dispose of batteries correctly.
Please dispose of the device in accordance with the legal obligation.

For transmitters rated at a maximum output power not listed above, the recommended 
separation distance (d) in meters (m) can
be estimated using the equation applicable to the frequency of the transmitter, where P is the 
maximum output power rating of the transmitter in watts (W) according to the transmitter 
manufacturer.

NOTE I At 80 MHz and 800 MHz. the separation distance for the higher frequency range applies. 

NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is 

Note: EMC tests conducted including attached electrode cord of 1.5 m length.   

 

The device is intended for use in an electromagnetic environment in which radiated RF 
disturbances are controlled.
The customer or the user of the device can help prevent electromagnetic interference by 
maintaining a minimum distance between portable and mobile RF communications 
equipment (transmitters) and as recommended below,  according to the maximum output 
power of the communications equipment. 

Rated maximum output 
power of transmitter

W

Separation distance according to frequency of transmitter

m

150 kHz to 80 MHz

 

d = 1.2 

80 MHz to 800 MHz

 

d = 1.2 

800 MHz to 2.5 GHz

 

d = 2.3 

0.01

0.12

0.12

0.23

0.1

0.38

0.38

0.73

1

1.2

1.2

2.3

10

3.8

3.8

7.3

100

12

12

23

TABLE 6: 

                    Recommended separation distances between
portable and mobile RF communications equipment and the device

Summary of Contents for Mytens BW-TSX

Page 1: ...ser Manual 072015 1 1 BW TSX 0197 Manufacture Nexmed Technology Co LTD Address 2nd Floor of No 1 building Jia An Technological Industrial Park 67 District Bao An 518101 Shenzhen China BW TSX Web site...

Page 2: ...e in case of anomalies or malfunction Electronic medical equipment requires special precautions regarding electromechanical com patibility It must be installed and used in accord with EMC ElectroMagne...

Page 3: ...s Do not place the electrodes near cancerous lesions because this may have a negative impact on these injuries Do not place the electrodes on skin areas whose sensations are not normal You may burn yo...

Page 4: ...ions Always consult your doctor or midwife if you are pregnant and intend to use the device cal muscle stimulation EMS device could in this case cause a blood clot In case of cognitive impairment If y...

Page 5: ...Strengthening of the muscular mass EMS 8 standard programmes Stimulation of the venous return TENS Easy to use Data transfer onto a phone or a Bluetooth 4 0 tablet 4 USE 4 1 DE See schema in page 8 SC...

Page 6: ...mage do not use the device or one of the electrodes Usable indoors and outdoors the device is not designed to withstand all weather conditions The device is not waterproof Do not wet it and never use...

Page 7: ...angerous However if you experience discomfort it is advisable to decrease the intensity of the programme change or move the electrodes The burst transcuta neous electrical neurostimulation Burst TENS...

Page 8: ...tion must remain comfortable and muscle contractions must not are advised to choose a low intensity to limit muscular fatigue SummaryTable of the EMS Programmes EMS Impulses Treatment site Name Treatm...

Page 9: ...harge the device fully before beginning a session If the charge is not complete at the beginning of a programme the battery may become deplete before the end of the session You cannot use the device w...

Page 10: ...g or biting sensation Note Always connect the device before you place the electrodes on the skin Note Do not place the electrodes on top of each other or so close to each other that they touch each ot...

Page 11: ...ensity lever you want Starting and stopping a treatment Tap the play button on the screen The treatment screen opens and the time starts to count down The status indicator on the device starts to flas...

Page 12: ...en stimulation is uncomfortable i e when you experience an unpleasant stinging or biting sensation Note Always replace the electrodes with electrodes recommended for this device by the manufacturer 5...

Page 13: ...9mmx55 8mm Programmes 19 programmes 11 TENS 8 EMS programmes Battery 3 7V 500mAh Li lon Output voltage max 60mA 10 1000 load Conditions of use 5 C to 40 C with a relative humidity of 15 to 93 atmosph...

Page 14: ...on electromagnetic IMMUNITY The customer or the user of these electrical stimulators should assure that it is used in such environment Immunity test IEC 60601 test level Compliance level Electromagnet...

Page 15: ...ith the legal obligation For transmitters rated at a maximum output power not listed above the recommended separation distance d in meters m can be estimated using the equation applicable to the frequ...

Page 16: ...Pain in the lower back Elbow Pain in the elbow Fore arm Pain in the forearm Wrist Pain in the wrist and carpal tunnel syndrome Hip Pain in the hip 12 Thigh Sciatic pain Knee Knee pain Lower leg Pain...

Page 17: ...ard will not be extended to another per including the user This guarantee covers only the defects of the material or parts occurring during normal use of the pro duct It does not cover the damage caus...