Open the door on hang-up on/off

Normally, the unit is set so that the entrance door is only

opened when the tenant dials 5 on his telephone dialpad. The

effect of this setting is that the door is also opened on hang-up

or time-out.

N.B. THIS FUNCTION MUST NOT BE USED WITH

ANSWER CHOICE 2.

Proceed as follows:

1 Go to the 

Options menu

 and browse to the 

Open on hang-up

function (follow the initial instructions in the 

Change call

duration time 

section on page 27). The following text is displayed:

/  TO SCROLL

OPEN ON HANG-UP

2 Press 

. The following text is displayed:

ENTER 1 (ON) / 0 (OFF)
(1)

3 Press 1 (means that the door is opened when the tenant

replaces the handset).

4 Press 

. The following text is displayed again:

/  TO SCROLL

OPEN ON HANG-UP

5 Press 

Esc

  to go back to the stand-by position or browse to

another function and continue programming.

4. PROGRAMMING

Summary of Contents for Telecode 5000

Page 1: ...1 Doc No 002 Issue 2 April 1998 Installation manual Telecode 5000...

Page 2: ...UK Material from the Telecode Installation Manual may only be copied with the consent in writing of Bewator Bewator reserves the right to alter both the content of the manual and the design of the pr...

Page 3: ...98 Documentnumber GBTC50000701 TableofContents 1Introduction 4 2Packagecontents 1 1 3Installation 1 3 4Programming 1 9 5Telecodeincompanies 3 6 6Technicalinformation 3 8 7Checklist 4 0 8UKStatutoryInf...

Page 4: ...gain access by entering a code number Telecode 5000 can also be used in businesses where visitors are received after office hours This is described in the Telecode in companies chapter later in this...

Page 5: ...three times in succession the code lock converts to sabotage mode and cannot be used To set it into operation again the correct entrance code must be entered twice in succession Intheapartment Since t...

Page 6: ...f the tenant s telephone is forwarded to another number calls from the door are also forwarded to this number The door can also be opened from this number according to the instructions above Selectthe...

Page 7: ...ard The tenant opens the door by pressing Open on the apartment phone then replaces the handset Telecodeandansweringmachines If an answering machine is connected to the number to call from the entranc...

Page 8: ...koneatatime During a call between the entrance phone and the telephone in the apartment only one person can talk at a time For the communicationen to work as smoothly as possible the partici pants sho...

Page 9: ...s going on from another phone in the system Lit following each keypress e g when entering a code Lit when the door is open Buttons 0 9 Used to enter an access code short code or telephone number A Pre...

Page 10: ...ow to install the system Programming step by step instructions on registering information in the system Telecode in companies describes how the entrance phone system should be used in companies e g if...

Page 11: ...code package should contain the follo wing 1 central unit 1 6 entrance phones 1 transformer 1 line cord with plug this manual and a user manual information sheet for the tenants Centralunit opened Rem...

Page 12: ...r visitors Loudspeaker EntrancephoneTP5 KeypadonlyM65doesnothaveloudspeaker Informationsheetfortenants PowerSupply Line cord with plug Installation and user manual User manual Telecode 5000 Installati...

Page 13: ...s about 95 cm The entrance phone is rated for temperatures between 35 and 55 C and can be mounted indoors as well as outdoors If the entrance phone is mounted outdoors you should seal screw and cable...

Page 14: ...the Preparations chapter in the user manual Also check that this person gets a copy of the user manual Connecting up To connect the different components in the entrance phone system proceed as follows...

Page 15: ...mation it needs to operate has been programmed To make sure everything has been done complete the check list on page 36 Important informtheusers Do not forget to inform the users about the system and...

Page 16: ...nded since it has built in lightning protection This will not work unless the unit is grounded 3 INSTALLATION TP5 Entrance Phone or M65 Keypad No 2 TC5000CentralUnit 6 TelePhoneLinePlug 2 1 2 3 4 5 6...

Page 17: ...ntral Unit enter 1 as the telephone number of the first apartment phone 2 as the telephone number of the second apartment phone etc see chapter 4 Programming 2 Address the next apartment phone by putt...

Page 18: ...y Drawn with the cover closed open when the cover is off Loudspeaker volume control Background lighting on off OFF ON Connectexitbutton andoptionalsurveillancecamera Exit push buttons and surveillance...

Page 19: ...Open the cover of the central unit using the key supplied 2 Use the keyboard when programming the information The display shows prompts telling what to do next Keys 0 9 Usedtoenterdigits Esc Used to l...

Page 20: ...d choose TIMES press 4 The following text is displayed 1 TIME OF DAY 2 TIME ZONES 2 Press 1 The following text is displayed ENTER TIME 13 35 In stand by position the following text is displayed 94 11...

Page 21: ...to be made to the date go straight to step 6 6 Press The main menu is displayed again Timezones Take out the Time zones chart and program the time zones to be used in the building 1 Choose TIMES 4 on...

Page 22: ...IME ZONE 2 8 Enter the desired time interval and days for the next time zone if more time zones are needed Otherwise press Esc The main menu is displayed Accesscodes Take out the Codes chart and progr...

Page 23: ...g text is displayed ENTER TIME ZONES 00 00 00 7 Enter during which time zones the code should be valid The code can be valid under three time zones at the most e g 01 02 and 10 If no time zone at all...

Page 24: ...yed OPENING TIME 1 999 7 4 Enter the desired lock activating time or keep the preset time 7 seconds 5 Press The following text is displayed TIME ZONE F DAY OPEN 0 DISABLED 0 6 Enter the number of the...

Page 25: ...the preset setting 0 13 Press The following text is displayed TIME ZONE FOR REGISTRATION 0 ALWAYS 0 14 Enter the number of the time zone to control printing to the printer If printing is to occur 24 h...

Page 26: ...lowing text is displayed WHICH DOORS 5 Enter in which door s the telephone number short code should be used 6 Press The following text is displayed ENTER TELE NO 0002 7 Program the next telephone numb...

Page 27: ...nge the call duration time proceed as follows 1 Press Esc three times when the central unit display is in stand by position The following text is displayed OPTIONS MENU 2 Press The following text is d...

Page 28: ...d to the calling time skip this section To change the calling time proceed as follows 1 Go to the Options menu and scroll to the Change calling time function follow the initial instructions in the Cha...

Page 29: ...code is to be used Proceed as follows 1 Go to the Options menu and scroll to the User def short code function follow the initial instructions in the Change call durationtimesectiononpage27 Thefollowi...

Page 30: ...ote Talk time starts from the end of dialling To set the Answering Choice function 1 Go to the Options menu and scroll to the Answering Choice function follow the initial instructions in the Change ca...

Page 31: ...ws 1 Go to the Options menu and browse to the Open on hang up function follow the initial instructions in the Change call durationtimesectiononpage27 Thefollowingtextisdisplayed TO SCROLL OPEN ON HANG...

Page 32: ...browse to the Open on busy tone function follow the initial instructions in the Change call durationtimesectiononpage27 Thefollowingtextisdisplayed TO SCROLL OPEN ON 2nd BUSY TONE 2 Press The followi...

Page 33: ...ons menu and scroll to the Edit Level of Registration function follow the initial instructions in the Change call duration time section on page 27 The following text is displayed TO SCROLL EDIT LEVEL...

Page 34: ...lowing text is dis played TO SCROLL PRINT EVENT LOG 3 Press The following text is displayed if the printer is not connected or not on line THE PRINTER IS NOT READY YET The following text is displayed...

Page 35: ...ve the Other options menu These are functions designed for changing the internal parameters There are no installer options here If is pressed when the Other options menu is displayed the following tex...

Page 36: ...telephone exchange but located in the same building can share a Telecode subscription The entrance phone calls the exchange of the of the desired company Used this way it is important to be able to op...

Page 37: ...elephone charges and a possible opening delay Up to three entrance phones can be connected in parallel so can call the same number Since companies often receive several visitors during office hours Te...

Page 38: ...entral unitsuppliespowertobothcentralunitandconnectedentrance phones Built in timer with back up power Remote opening function Adjustable lock activating time 1 999 seconds Built in lightning protecti...

Page 39: ...ssue 2 April 1998 Entrancephones Impact resistant cast housing with stainless steel buttons Background lighting can be switched off Temperature range 35 to 50 Dimensions 200 x 80 x 30 mm HxWxD 6 TECHN...

Page 40: ...ns when you enter a programmed access code on the entrance phone do not forget that the current time zone must be valid that the telephones in the apartments can be called using the programmed short c...

Page 41: ...ved for connection to the Public Switched Telephone Network provided by British Telecommunications plc Kingston upon Hull City Council and Mercury Communications Ltd REN REN Ringer Equivalence Number...

Page 42: ...r Auto calling In order to minimize the risk of inconvenience to other network subscribers users are advised to carefully check all numbers entered during the set up of stored numbers prior to dialing...

Page 43: ...proval of the apparatus if as a result it then ceases to conform to the standards against which approval was granted Connection of power supply The TC5000 is intended for use when powered by a Tufvass...

Page 44: ...o the TC5000 ports only circuits having the same safety status should be interconnected The TC5000 is not fitted with a mains isolation switch and should there fore be installed near to an accessible...

Page 45: ...Bewator Group Ltd Albany Street Newport South Wales NP20 5XW Tel 44 0 1633 821000 Fax 44 0 1633 850893 E mail helpdesk bewator cotag com...

Reviews: