16
Doc. No. 002 Issue 2 April 1998
Wiring diagrams
Connect entrance phones, plug and transformer
The diagram below shows how to connect the entrance phone
to the central unit and the lock, and where the transformer,
plug and printer (if any) should be connected.
Note!
It is crucial that the central unit is grounded, since it has built-
in lightning protection. This will not work unless the unit is grounded.
3. INSTALLATION
TP5 Entrance Phone
or M65 Keypad No.2
TC 5000 Central Unit
6
TelePhone Line Plug
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
1
2
3
4
5
6
7
8
1
2
3
4
5
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
TP5 Entrance Phone
or M65 Keypad No.1
Fail Safe Connection
PL 1
PL 2
PL 3
1
3
4
5
Connections
for
Remaining
4
Doors
2
3
4
5
6
1
DTR
Data
0 Volt
Transformer
Red
White
Ground
Printer
Connection