background image

 

OPERATING TIPS

 

 

Always inspect wheel brakes before attempting to move the cabinet. Make certain that brakes are in the 

locked position before placing cabinet into operation. 

 

During "cold" start-up you may want to set the Humidity Control to the HI setting for 10 to 15 minutes to 

accelerate the humidity process. Remember to re-set the Humidity Control back to the desired setting 

before beginning the proofing process. Once the cabinet has been loaded with product and the proofing 
process has started, the door(s) should not be opened until proofing has been completed. 

 

The  18"  x  26"  sheet  pan  (not  provided)  that  serves  as  a  drip  pan  under  the  cabinet  base  should  be 

checked, and if necessary, emptied at the end of each day. 

 

The cabinet should be cleaned whenever necessary. It should be thoroughly cleaned at least once a week. 

 

Note: 

It is recommended that humidity be kept at the minimum level that is practical for your operation. 

Excessive humidity with condensation on the walls and/or base of the cabinet is not considered desirable. 

 

SAFETY AND HEALTH

 

 

BevLes  Proofing/Holding  Cabinets  meet  all  cUL  and  NSF  requirements.  Always  operate  this  unit  in 
accordance  with  the  operating  instructions  found  in  this  manual.  Never  remove  the  humidity-heating 

module without first disconnecting (unplugging) the unit from its power source. The cabinet is designed 

and built for easy cleaning. It should be cleaned frequently as described in the maintenance section. 

 

MAINTENANCE

 

 

Cleaning: This cabinet was designed and built for maximum sanitation. It is not self cleaning, so it should be 

cleaned frequently with soap and water. 

 

1.  NEVER USE STEEL WOOL OR CAUSTIC CLEANING COMPOUNDS. 

2.  Make sure that the unit is turned OFF and 

disconnected

 from the electrical service. 

3.  Remove  the  polycarbonate  water  pan  cover  and  side  covers  from  the  humidity-heating 

module. 

4.  Remove the pan supports and vertical uprights. 
5.  Remove the vent from the rear wall. 
6.  Clean inside of cabinet with soap and water. Clean clear polycarbonate water pan cover and 

door(s) with soft sponge, soap and water. 
NEVER USE HARSH CLEANING SUBSTANCES OR ABRASIVES TO CLEAN LEXAN® 

SURFACES, OR THE CAST ALUMINUM WATER PAN. 

7.  Remove and clean the 18" x 26" drip pan (not provided) from under the cabinet base 

 

If necessary, the humidity-heating module can be removed by loosening the two (2) black knobs (one 

located at each side on the module on the exterior of the cabinet). The module can be pulled out of the 

cabinet for additional cleaning. We suggest that you clean the water pan at least once a month with a 

solution of white vinegar and hot water. Allow white vinegar to remain in water pan overnight. Then use a 
soft cloth to wipe away any mineral buildup. 

 

Important: 

When placing the humidity heating module back into the cabinet  make certain that the module 

is pushed tightly against the cabinet and secured with the two (2) black knobs. Check to see that the one 

inch air flow opening at the rear of the humidity-heating module is behind the back vent that hangs on the 

rear  wall  of  the  cabinet.  This  is  necessary  to  maintain  uniform  temperature  and  humidity  distribution 
throughout the cabinet. 

 

IF  REPLACEMENT  PARTS  ARE  EVER  REQUIRED,  ONLY  USE  PARTS  THAT  HAVE  BEEN 

APPROVED BY BEVLES COMPANY, INC. 

 

Summary of Contents for PHC70-32-A

Page 1: ...ce when used according to the instructions in this manual and standard commercial kitchen practices Toll Free 844 265 0250 Fax 800 548 9392 Website www BevLes com E mail sales BevLes com 05 19 BevLes...

Page 2: ...6 Assistance Service 7 Trouble Shooting 7 Additional Information 8 Wiring Diagrams 9 10 11 12 Parts List 13 Warranty 15 SAFETY PRECAUTIONS Before installing and operating this equipment be sure every...

Page 3: ...ust comply with the Canadian Electrical Code CSAC22 2 as applicable NOTICE Local codes regarding installation vary greatly from one area to another The National Fire Protection Association Inc states...

Page 4: ...erials tape cardboard etc 5 Carefully lift cabinet off pallet 6 Check model number on the serial number label located on the back of the unit 7 Release all wheel brakes SETTING UP 1 Remove all protect...

Page 5: ...ur application 5 Set the humidity control to the 3 or 4 position This can be increased if necessary to suit your specific application 6 Make certain that a standard 18 x 26 sheet pan not provided has...

Page 6: ...ss the SETkey the temperature setting will revert back to previous setting 6 Set the humidity control to the 3 or 4 position This can be increased if necessary to suit your specific application 7 Make...

Page 7: ...m sanitation It is not self cleaning so it should be cleaned frequently with soap and water 1 NEVER USE STEELWOOLOR CAUSTIC CLEANING COMPOUNDS 2 Make sure that the unit is turned OFF and disconnected...

Page 8: ...ect water level in the water pan 2 Check the humidity control knob to see if it is set where you normally operate at 3 Check to see if the cabinet door s is closed 4 Make certain that the humidity hea...

Page 9: ...screws 3 and stainless steel drip edge 5 Turn module over and remove screws from the bottom of the module 6 screws each side There will be 4 nylon caps and spacers save and reuse 6 Remove screws from...

Page 10: ...120v Solid State Control Amp rating 16 7 amps...

Page 11: ...120v Digital Control Amp rating 16 7 amps...

Page 12: ...208 230v Solid State Control Amp rating 9 7 8 7 amps...

Page 13: ...208 230v Digital Control Amp rating 9 7 8 7 amps...

Page 14: ...et Mounting Sensor 750420 Slide Glide Pan Support 740348 Vertical Upright 1 50 Spacing 1488400 Thermostat 80 180 Degree 120 240v 784662 Temperature Controller Digital 120 240v 1302400 Switch Rocker DP...

Page 15: ...Notes...

Page 16: ...all be void in its entirety if any abuse of misuse of alteration modification of or improper maintenance of original product occurs If at any time a claim is reported to Bevles and the purchaserisdeli...

Page 17: ...vative Foodservice Equipment Custom Designed for Performance Service and Value Toll Free 844 265 0250 Fax 800 548 9392 Website www BevLes com E mail sales BevLes com BevLes 1525 East Lake Rd Erie Pa 1...

Reviews: