Free NiBG Alarm
While operating in Free Dive mode, residual Nitrogen remain-
ing from the Free Dives and any previous NORM SCUBA Dives
conducted within 24 hours is displayed as the NiBG.
When Nitrogen loading increases to the Caution level, 3 short
beeps will sound 3 times; and 7 NiBG No Deco segments and
the graphic NibG will be displayed (flashing) (Fig. 94).
After the beeps, the Main will be restored with the NiBG flash-
ing until it recedes to 6 segments or 10 minutes on the surface.
In the event that Nitrogen loading increases to the Deco level,
operation will enter Violation Gauge Mode for 24 hours.
Entry into Deco (Violation)
Upon entry into Deco, 3 short beeps will sound 3 times, the full
NiBG (all 8 segments) together with the graphics GoUP - VioL
will be displayed flashing (Fig. 95).
Upon surfacing, the graphic will be removed, the NiBG continu-
ing to flash until it recedes to 6 segments or after 10 minutes at
which time operation will enter Violation Gauge Mode for 24
hours. The graphic VIO will then alternate with FRE for 24 hours
during which operation will lock into Violation Gauge Mode
blocking access to NORM and GAUG modes.
Fig. 95 - FREE VIOLATION
(entry into Deco)
Fig. 94 - FREE NIBG ALARM
(during audible)
Summary of Contents for VOYAGER-2G
Page 1: ......
Page 7: ...7 OVERVIEW...
Page 15: ...15 FEATURES AND DISPLAYS...
Page 21: ...21 SURFACE MODES...
Page 45: ...45 NORM DIVE MODES...
Page 53: ...53 CAUTIONARY MODES...
Page 65: ...65 SWITCHING GAS MIXES...
Page 69: ...69 NORM POST DIVE MODES...
Page 73: ...73 GAUGE OPERATING MODE...
Page 77: ...77 FREE DIVE OPERATING MODE...
Page 89: ...89 GENERAL...
Page 106: ...2002 Design 2010 Doc No 12 27925 r01 7 12 10...