Menu
Conductivity Mode
Timed Mode
1
1
2
2
1 - Conveyor
2 - Door
1 - Conveyor
2 - Door
3 - Door with external
3
VCP Concentration
Reading
- - -
4
Concentration Set
Point 0-70
Detergent Recharge 0-
20 seconds
5
- - -
Detergent Initial Charge
0-240 seconds
6
Rinse Delay 0-240 sec Rinse Delay 0-240 sec
7
Rinse Speed 0-99%
Rinse Speed 0-99%
8
Rinse Run Time Limit
0-240 sec
Rinse Run Time Limit 0-
240 sec
9
Wash Temp 0-100
degrees C
- - -
10
Alarm Volume 0 min-5
max
Alarm Volume 0 min-5
max
11
Not used
Not used
12
Not used
Not used
Menu
Conductivity Mode
Timed Mode
13
Detergent Speed 0-99%
Detergent Speed 0-99%
14
15
Sanitizer Speed 0-99%
Sanitizer Speed 0-99%
16
PCB ID Code
PCB ID Code
17
Rack Count High (0-240)
1,000,000's, 100,000's &
10,000's
Rack Count High (0-240)
1,000,000's, 100,000's &
10,000's
18
Rack Count Middle (0-99)
1,000's & 100's
Rack Count Middle (0-
99) 1,000's & 100's
19
Rack Count Low (0-99)
10's & 1's
Rack Count Low (0-99)
10's & 1's
20
Drain Count (0-240)
Not available
21
Conductivity Range
0 = LO 1 = HI
- - -
22
Concentration Reading
without VCP
- - -
23
Control Source
0 = Knobs/dial control
1 = Uniview control
Control Source
0 = Knobs/dial control
1 = Uniview control
24
Firmware Version Firmware Version
Sanitizer Feed: 0 = on with rinse, 1 = on with
detergent, 2 = on with rinse, low level stops all
pumps, 3 = on with detergent, low level stops all
pumps
Programming Chart Reference