2.
If in probe mode, make the UniView setpoint 0 or short the probe wires to keep
the unit from alarming.
3. Fill tank and use prime button to add some detergent so you can titrate the tank.
If it’s a probeless installation, use a stopwatch to count the seconds of pump on time
so you can program initial charge.
a. Take sample of tank water in 10 ml vial
b. Add 3-5 drops of Phenolphthalein solution
c. Swirling vial around in circles to mix, add sulfuric acid drop by drop,
counting the drops
d. Compare to the chart on the following page:
WEIGHT/PRODUCT FACTOR=TARGET # DROPS
•If more drops required than the result, add more detergent
•If less drops required than the test result, decrease the amount of detergent
•When you’ve reached the right number of drops, check the Beta Unit reading and
use that as the setpoint; if in time mode, use the seconds counted on the stopwatch
for initial charge.
Note: Be sure to follow the directions in your titration kit, in case they differ from
those above.
Tank Titration:
Step 2 = Titrate for setpoint & tank fill