16
OPERATION MANUAL AND INSTRUCTIONS
EN
SETTING TORQUE-ANGLE VALUES
1
3
2
4
1 - Read in values
2 - Select/Set unit of measurement
3 - Set driving torque/angle
4 - Power on / Clear
Fig. 3
The required torque-angle values can be set in just a few steps, through the physical buttons (Fig. 3) of the display, as follows:
STEP 1: PRESETTING MEMORIES
The device allows up to 9 torque/angle values to be set and stored in as many memories. This results in shorter adjusting times
in case a few values should be repeated quite frequently. To switch between memories, press . The number of the memory
is displayed on the screen. For each memory, set the UNIT OF MEASUREMENT and the TORQUE/ANGLE VALUE as shown
in the following steps.
Read-in value:
M1
Press
Read-in value:
M2
Press
Read-in value:
M3
Read-in value:
M9
NOTE:
If appears, that means more than 110% of torque as stated in the specifications has been applied to this wrench.
M
M
M