background image

MAINTENANCE

• Make sure that the Filter Pump is unplugged before any maintenance.

• For the maintenance instructions, refer to illustration steps     inside the manual. Drawings are for illustration purposes 

only. May not reflect actual product. Not to scale.

• To optimize the Filter Pump performance and for sanitary reasons, we suggest replacing the filter cartridge with a new 

one every two weeks.

INSTALLATION

SETUP

CHECK LIST 

To check the parts included in the box, consult the part list inside this manual. Verify that the equipment components 
represent the model that you had intended to purchase. In case of any damaged or missing parts at the time of purchase, 
visit our website bestwaycorp.com/support. 

CHOOSE THE CORRECT LOCATION

Place the Filter Pump on a solid and level ground; it must be positioned on the same level as the base of the pool. If the 
Filter Pump is in an upper or lower position than the base of the pool, the performance and life span of the Filter Pump can 
be compromised. The pool and the Filter Pump have to be positioned in an area with adequate drainage and easy access 
for maintenance operations. Never place the Filter Pump in a area that may accumulate water.

ATTACHING A BASE

FOR 330GAL

EN60335-2-41 TEST standard requires the filter pump to be vertically fixed 
on the ground or a base made of wood or concrete before use. There should 
be two holes 9 mm in diameter on the base, the space between which 
should be 127 mm. Put filter pump on the base and attach them together 
by fastening the bolts and nuts. All the base parts should weigh at least 
over 18 kg to prevent the pump from accidentally falling.

5

390 127

40

390

250

127

2-M8 nut
2-M8 bolt

FOR 530GAL

EN60335-2-41 TEST standard requires the filter pump to be vertically fixed 
on the ground or a base made of wood or concrete before use. There should 
be two holes 9 mm in diameter on the base, the space between which 
should be 159 mm. Put filter pump on the base and attach them together 
by fastening the bolts and nuts. All the base parts should weigh at least 
over 18 kg to prevent the pump from accidentally falling.

390 159

40

390

250

159

2-M8 nut
2-M8 bolt

FOR 800GAL

EN60335-2-41 TEST standard requires the filter pump to be vertically fixed 
on the ground or a base made of wood or concrete before use. There should 
be two holes 9 mm in diameter on the base, the space between which 
should be 166 mm. Put filter pump on the base and attach them together 
by fastening the bolts and nuts. All the base parts should weigh at least 
over 18 kg to prevent the pump from accidentally falling.

390 166

40

390

250

166

2-M8 nut
2-M8 bolt

WARRANTY TERMS

For information concerning warranty terms, visit our website at: www.bestwaycorp.com.

STORAGE

• Remove all accessories; be sure that Filter Pump, hoses and debris screens are completely clean and dry before the 

storage. If all the parts are not completely dry, mold may result.

• Before storage, remove and dispose of the filter cartridge.
• We strongly recommend disassembling the Filter Pump when the environment temperature is below 10ºC / 50ºF.
• Store the Filter Pump in a dry place with a moderate temperature between 10ºC / 50ºF and 38ºC / 100ºF.

• For the installation instructions, refer to the illustration steps     inside the manual. Drawings are for illustration purposes 

only. May not reflect actual product. Not to scale.

• Bestway will not be responsible for any damage caused to the Filter Pump due to mishandling or failure to follow these 

instructions.

• It is imperative to check that the hydraulic connectors are not obstructed.
• Do not dry run the Filter Pump. Make sure both the pool's inlet and outlet valves are fully covered by water before 

operating the Filter Pump.

Summary of Contents for FlowClear 58383

Page 1: ...EN DE NL FR OWNER S MANUAL bestwaycorp com support Visit the Bestway YouTube channel...

Page 2: ...ch it on the website www bestwaycorp com support WARNING The pump is to be supplied by an isolating transformer or supplied through a residual current device RCD having a rated residual operating curr...

Page 3: ...ilter clogging level A weekly check is recommended for cleaning Minimum daily filtration operating time of 8 hours is recommended to ensure clear pool water It is essential to change any damaged eleme...

Page 4: ...ry the pump by the power cord Never pull a plug from the outlet by yanking the power cord Keep cord free from abrasions Sharp objects oil moving parts and heat should never be exposed to the filter pu...

Page 5: ...ertically fixed on the ground or a base made of wood or concrete before use There should be two holes 9 mm in diameter on the base the space between which should be 159 mm Put filter pump on the base...

Page 6: ...wand sollte mehr als 4 m vom Schwimmbecken in einer H he von mindestens 1 2 m angebracht sein Das Pumpenaggregat darf nur mit Kleinspannung entsprechend der Kennzeichnung auf dem Ger t betrieben werde...

Page 7: ...gung empfohlen Pro Tag wird eine Filterzeit von mindestens 8 Stunden empfohlen Besch digte Komponente m ssen so schnell wie m glich ausgetauscht werden Verwenden Sie daf r ausschlie lich die vom Herst...

Page 8: ...ei von Absch rfungen Die Filterpumpe darf niemals mit scharfen Gegenst nden l beweglichenTeilen und Hitze in Ber hrung kommen Die Reinigung und Wartung m ssen von einer erwachsenen Person durchgef hrt...

Page 9: ...erden muss Auf dem Sockel sollten zwei L cher mit einem Durchmesser von 9 mm vorhanden sein der Abstand zwischen ihnen sollte 159 mm betragen Setzen Sie die Filterpumpe auf den Sockel und befestigen S...

Page 10: ...rde elektricien voor eventuele vragen De stroombron op de muur van het gebouw moet meer dan 4 m verwijderd zijn van het zwembad en op een hoogte van ten minste 1 2 m De pompunit mag alleen worden gevo...

Page 11: ...menten zo snel mogelijk te vervangen Gebruik alleen onderdelen die zijn goedgekeurd door de persoon die verantwoordelijk is voor het op de markt brengen van het product Alle filters en filtermedia moe...

Page 12: ...nooit een stekker uit het stopcontact door aan het netsnoer te trekken Houd het snoer vrij van beschadiging Scherpe voorwerpen olie bewegende delen en hitte mogen nooit worden blootgesteld aan de fil...

Page 13: ...rticaal op de grond of op een basis van hout of beton wordt bevestigd Er moeten twee gaten met een diameter van 9 mm op de basis zijn met een tussenruimte van 159 mm Zet de filterpomp op de basis en b...

Page 14: ...e d passant pas 30 mA Consultez un lectricien qualifi pour toute question La source de courant sur le mur du b timent ne doit pas tre plus de 4 m de la piscine et une hauteur de 1 2 m au moins La pomp...

Page 15: ...i rement le niveau de remplissage du filtre Une v rification hebdomadaire est recommand e pour le nettoyage Une dur e minimale de fonctionnement de la filtration de 8 heures par jour est recommand e p...

Page 16: ...on d alimentation Ne retirez jamais une fiche de la prise en tirant sur le cordon d alimentation Veillez ce que le cordon ne soit pas ab m La pompe de filtration ne doit jamais tre mise en contact ave...

Page 17: ...e verticalement sur le sol ou sur une base en bois ou en b ton avant d tre utilis e Il doit y avoir deux trous de 9 mm de diam tre sur la base l espace entre eux devant tre de 159 mm Placez la pompe d...

Page 18: ...2 3 1 1 2 3 4 B A A B B A A B B A x4 B A 1 min 1 x1 7 x2 8 x4 9 x1 10 x1 2 x1 3 x1 4 x1 5 x1 6 x2 18...

Page 19: ...1 2 3 4 1 2 3 4 A B A B A B x4 1 min 19...

Page 20: ...r Hergestellt vertrieben und in der Europ ischen Union vertreten von Prodotto distribuito e rappresentato nell Unione Europea da Bestway Europe S p a Via Resistenza 5 20098 San Giuliano Milanese Milan...