5. Overall View of the water softener appliance 

1

 

The control system is the most important part 

of the softening appliance. Its functioning 

technique is based on ceramic plate technol-

ogy, which is dependent on the relative posi-

tion to one another, which generate succes-

sive work and revitalisation cycles. 

The water softener is factory-ready and will 

work immediately after connection. Only the 

time of day, the water hardness and the revi-

talisation time have to be entered. 

 

The bypass is another important element that 

accomplishes several important functions in 
the operation of the water softening system. 

Thanks to this bypass, it is possible to quickly 

and easily remove or add the water softener 

in to or out of the existing water installation. 

In addition, you can adjust the water flow in 

the system, so that softened water or normal 

tap water flows through. The bypass can also 

handle mixing functions. 

 

The tank is filled with a filter which allows ion 

exchange. For optimal operation of the device, 

the filter should be replaced at least every 10 

years (depending on the water quality and  

water hardness). 

 

The body of the appliance is made of durable, flexible plastic. It acts as a salt and brine tank. 

Inside there is mounted a cylinder with a filter, an ion exchanger and a float valve. Check and 

control the level of the brine in the tank - Protect the unit from overfilling. There is an over-

flow pipe on the side wall of the housing.  

 

5

 

The float valve regulates the refilling process of water and supplies the saline solution. Proper 

functioning ensures the correctness of the revitalisation process. 

 

 

Summary of Contents for BW 1500

Page 1: ...1 Instruction Manual BW 1500 Stationary water softening appliance with control system RX 79BD 82BD Edition 1 2020...

Page 2: ...www bestwater de 2...

Page 3: ...it 12 10 Setup of the water softeners 14 11 first time of Usage 15 11 1 Vent the installation 15 11 2 First Regeneration 16 12 Operation of the water softener 16 12 1 Checking the salt inventory and f...

Page 4: ...e used for its intended purpose Failure to observe the conditions of use contained in the instructions will invalidate the guarantee Do not interfere with the design of the softener Changes to the des...

Page 5: ...main supply line into your home This water is passed into the water softening appliance which flows through the ion ex changer which softens the water The treated water then flows into the water syste...

Page 6: ...5 45 Operation pressure Ba 2 6 Average salt consumption per regeneration kg 2 4 Possibility of taking water from the network during re generation Yes regeneration behaviour Volumetrically delayed typ...

Page 7: ...softener in to or out of the existing water installation In addition you can adjust the water flow in the system so that softened water or normal tap water flows through The bypass can also handle mi...

Page 8: ...e water filled system The ambient temperature should never drop below 5 C otherwise the device can be permanently damaged It is not advisable to install the devices in rooms with high humidity The loc...

Page 9: ...C Look for the flow direction arrows on the control head on the water inlet and outlet connec tion The turbine should be at the outlet of the device Before assembly check that the tur bine is rotating...

Page 10: ...drain with a flexible hose The sewage connections must be installed below the level of the salt pool in the storage con tainer so that the overflowing water can drain off without pressure After conne...

Page 11: ...possible with a pres sure reducer with at least 50 micron filter All connections must be made in accordance with the applicable guidelines and standards The subsurface must be level and able to bear...

Page 12: ...cted to the control valve Please protect from children 9 Description of the control unit The RX control unit is equipped with a microcomputer with which the operating parameters of the water treatment...

Page 13: ...layed the keyboard is locked This function is activated after one mi nute of inactivity To activate the keyboard one should press the and buttons simulta neously for min 5 seconds until the blockage s...

Page 14: ...you press during the setup mode the process will go back into the menu before When entering a parameter value the button takes you back to the parameter selection without saving the value 10 Setup of...

Page 15: ...LR3 will be shown The value 02 of the Parameters is blinking and can be changed with and 3 Press again the value 00 starts to blink with and can you change the value 4 Press again and the settings wi...

Page 16: ...l setting The Regeneration runs automatically and after the first regeneration the system is ready for operation 12 Operation of the water softener 12 1 Checking the salt inventory and filling up the...

Page 17: ...ch is re sponsible for the introduction of the brine can be blocked If a sediment filter drawing F is installed in front of the water treatment system and the salt is of sufficient quality the injec t...

Page 18: ...neration with salt and slow rinsing The container slowly fills with fresh water As soon as the container is completely filled the con tents together with the used brine are drained into the sewage sys...

Page 19: ...an control unit and resin Increase the regeneration fre quency and or extend the dura tion of the backwash Pressure fall The inlet to the control unit is blocked by remnants of the installation Clean...

Page 20: ...guarantee for the trouble free operation of the water softener provided that it was operated according to the instructions in this manual and with regular refilling of the salt The stationary water so...

Page 21: ...improper storage of the device and the consumables consequences resulting from the decommissioning of the product mechanical damage to the device The buyer loses the guarantee for the following reaso...

Page 22: ...ion sheet THE USER SHOULD MAKE SURE THE INSTALLER COMPLETES THE CORRESPONDING LINES IN THE TABLE Device put into operation by Pipe installation Date Name Company name Tel electrical Installation Date...

Page 23: ...23 1 2020...

Page 24: ...7 14547 Beelitz GERMANY Contact E Mail info bestwater de Internet www BestWater de Online Shop www Bwishop de Tel 49 33204 62 86 0 Fax 49 33204 62 86 11 HRB 26901 P USt IdNr DE293844629 Data protectio...

Reviews: