Drawing B.
Cross section of the device
1 container
2 tank cover
3-bypass
4 resin container
5-Upper basket
6 lower basket
7-pipe
8-the salt valve with float
9-salt container
10 control head
11-LCD display
12 flange key for control head
The regeneration water drainage from the control head can be connected to the sewage sys-
tem using a flexible ½ “hose.
The overflow mounted on the device housing should also be connected to the sewer drain
with a ½ “flexible hose.
The sewage connections must be installed below the level of the salt pool in the storage con-
tainer so that the overflowing water can drain off without pressure.
After connecting the softener, the storage container should be filled with regeneration salt
tabs. The regeneration salt level should always be higher than the water level in the storage
container. If necessary, the regeneration salt should be refilled so that the salt pool is availa-
ble in sufficient quantity for the upcoming regeneration processes. Table 2 shows the average
regeneration salt consumption.