background image

WARNING!

5

•  NO

 modification of this equipment is allowed. It is unsafe to modify the 

 

equipment from its original state. This product is deemed safe to use with  

only the original parts as delivered. Unauthorized use of any modified 

 

equipment may result in serious injury or death.

•  DO NOT 

replace any components of the lift without consulting with  

Bestcare and must follow proper instruction from Bestcare when replacing  

any components.

•  DO NOT

 service any parts of the lift while in use with a patient.

•  It is 

NOT

 safe to load the equipment more than the indicated maximum safe  

working load.

•  IF

 any accessories with lower load capacity than the equipment itself is used, 

DO NOT

 load the equipment more than the lowest maximum safe  

working load.

•  This equipment 

DOES NOT

 consist of any materials or ingredients to  

which patients are exposed, that may cause bodily harm or injury. 

•  Prolonged exposure or physical contact with any part of the equipment 

WILL  

NOT

 cause skin irritation, allergic reaction, etc.

•  Using accessories, detachable parts, or materials not described in the  

instruction manual 

MAY RESULT IN SERIOUS INJURIES.

•  Keep the equipment away from children and pets when in use. 

IT MAY  

CAUSE SERIOUS INJURY OR DEATH.

•  Keep the equipment away from any pests or pest infested area. Diseases  

transferred from pests to the equipment 

MAY CAUSE SERIOUS ILLNESS

  

to patients upon contact.

•  If the lift is exposed to the sun for long periods of time, be 

CAUTIOUS

  as the  

surface of the lift may be hot.

•  There are no risk if the lift is exposed to reasonably foreseeable  

environmental conditions

•  DO NOT

 use the lift on an inclined surface that is greater than 5°.

•  CAUTION! 

The black plastic bolt caps can fall off the bolt, and they are a  

choking hazard. 

If the cap will not stay on the bolt, replace it immediately.

Summary of Contents for BestMove STA400

Page 1: ...R A I D M o d e l S T A 4 0 0 S T A 4 5 0 Ensure the product has been assembled according to the instructions in this manual All operators should read and understand the instructions for safe and prop...

Page 2: ...h BestMove STA400 Max Load 400lb 182kg S N STA400YYMM1XXX 2920 Pacific Dr Norcross GA 30071 1 678 679 6690 Mass of Lift 60lb 27kg To better serve you please record the following information for future...

Page 3: ...to form a secure and comfortable seat for the user to sit on for the remainder of the transfer The STA450 has a opening base to work with wide range of wheelchairs and furnitures The STA400 and STA450...

Page 4: ...physical contact with the patient in order for the device to carry out its intended Do Not Iron Item may not be smooted or finished with an iron Class II symbol To identify equipment is designed that...

Page 5: ...kers discretion i e patients who are comatose spastic agitated or otherwise severely handicapped The patient lift should be used solely for transferring a user patient from one utility beds chairs toi...

Page 6: ...dients to which patients are exposed that may cause bodily harm or injury Prolonged exposure or physical contact with any part of the equipment WILL NOT cause skin irritation allergic reaction etc Usi...

Page 7: ...IVE NORCROSS GA 30071 PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BESTCARE LLC ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION...

Page 8: ...0 mm 26 5 674 mm C Base Int Width Opened N A 31 8 808 3 mm D Lift Overall Height 43 3 1099 mm 43 3 1099 mm E Front Caster Height 4 7 119 mm 4 7 119 mm F Seat Pad Height 33 9 861 mm 33 9 861 mm G Knee...

Page 9: ...rms Align the holes on each ends of handle bar with the holes on the arm and secure the handle bars to the arms using screws as follows Step 2 Connect the two mast to the left and right arms align the...

Page 10: ...p 4 Insert the two kneepads into the kneepad crossbeam and secure the kneepad with hex bolts split washers washers Cover the bolt head with plastic cover Step 5 Insert the kneepad crossbeam to the mas...

Page 11: ...e patient with optimal safety Never interfere with the lift unless instructed by the attendant Have a doctor nurse or medical attendant experienced in the use of the BestMove present during the first...

Page 12: ...Have the patient grasp the cross bar closest to them and using their own strength pull themselves up into a standing position on the footplate platform If the patient needs assistance pulling themselv...

Page 13: ...ok one of the hooking loops to the hook on the arm 4 Pull on the other hooking loop to assist the patient to stand up 5 Once the patient is seated on the seat pad hook the other hooking loop onto the...

Page 14: ...isual inspection prior to use for the additional points below V The periodic inspection interval and the visual inspection points are listed below Note Bestcare assumes that the assembly instructions...

Page 15: ...suance of a return authorization will also be refused as the authorization will have expired The final disposition of warranty claims will be subject to our inspection of the returned items Bestcare L...

Page 16: ...Bestcare LLC 2920 Pacific Drive Norcross GA 30071 Ver 2021 09 www bestcarellc com 2021 Bestcare LLC...