Intended Use

The BestMove® STA400 and STA450 allow patients up to 

400lbs and 450lbs, respectively, to be transferred safely with 

minimal physical effort provided by the operator.  Transferring 

functions of all types are quick and require minimal caregiver 

assistance. Each unit is equipped with a crossbar where users 

can grasp and pull themselves up into a standing position using 

their own strength. The caregiver then flips the padded seats 

back into place to form a secure and comfortable seat for the 

user to sit on for the remainder of the transfer. The STA450 has 

a opening base to work with wide range of wheelchairs and 

furnitures.

The STA400 and STA450 are intended to be used with patients 

who are immobile, but have enough leg strength to stand 

themselves up. The STA400 and STA450 are intended to be 

used for transfers of the patient between bed, chair, wheelchair,  

and the commode. The STA400 and STA450 are intended to 

be operated by at least one caregiver, who will perform the 

transfer.  Transfers should always be done on a flat, dry surface 

and are not intended to be used in high humidity environments 

for extended amounts of time.

Summary of Contents for BestMove STA400

Page 1: ...R A I D M o d e l S T A 4 0 0 S T A 4 5 0 Ensure the product has been assembled according to the instructions in this manual All operators should read and understand the instructions for safe and prop...

Page 2: ...h BestMove STA400 Max Load 400lb 182kg S N STA400YYMM1XXX 2920 Pacific Dr Norcross GA 30071 1 678 679 6690 Mass of Lift 60lb 27kg To better serve you please record the following information for future...

Page 3: ...to form a secure and comfortable seat for the user to sit on for the remainder of the transfer The STA450 has a opening base to work with wide range of wheelchairs and furnitures The STA400 and STA450...

Page 4: ...physical contact with the patient in order for the device to carry out its intended Do Not Iron Item may not be smooted or finished with an iron Class II symbol To identify equipment is designed that...

Page 5: ...kers discretion i e patients who are comatose spastic agitated or otherwise severely handicapped The patient lift should be used solely for transferring a user patient from one utility beds chairs toi...

Page 6: ...dients to which patients are exposed that may cause bodily harm or injury Prolonged exposure or physical contact with any part of the equipment WILL NOT cause skin irritation allergic reaction etc Usi...

Page 7: ...IVE NORCROSS GA 30071 PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BESTCARE LLC ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION...

Page 8: ...0 mm 26 5 674 mm C Base Int Width Opened N A 31 8 808 3 mm D Lift Overall Height 43 3 1099 mm 43 3 1099 mm E Front Caster Height 4 7 119 mm 4 7 119 mm F Seat Pad Height 33 9 861 mm 33 9 861 mm G Knee...

Page 9: ...rms Align the holes on each ends of handle bar with the holes on the arm and secure the handle bars to the arms using screws as follows Step 2 Connect the two mast to the left and right arms align the...

Page 10: ...p 4 Insert the two kneepads into the kneepad crossbeam and secure the kneepad with hex bolts split washers washers Cover the bolt head with plastic cover Step 5 Insert the kneepad crossbeam to the mas...

Page 11: ...e patient with optimal safety Never interfere with the lift unless instructed by the attendant Have a doctor nurse or medical attendant experienced in the use of the BestMove present during the first...

Page 12: ...Have the patient grasp the cross bar closest to them and using their own strength pull themselves up into a standing position on the footplate platform If the patient needs assistance pulling themselv...

Page 13: ...ok one of the hooking loops to the hook on the arm 4 Pull on the other hooking loop to assist the patient to stand up 5 Once the patient is seated on the seat pad hook the other hooking loop onto the...

Page 14: ...isual inspection prior to use for the additional points below V The periodic inspection interval and the visual inspection points are listed below Note Bestcare assumes that the assembly instructions...

Page 15: ...suance of a return authorization will also be refused as the authorization will have expired The final disposition of warranty claims will be subject to our inspection of the returned items Bestcare L...

Page 16: ...Bestcare LLC 2920 Pacific Drive Norcross GA 30071 Ver 2021 09 www bestcarellc com 2021 Bestcare LLC...