10
Figure 15
4: If you want to hang on the wall, turn the
DC plug
down until 0 degrees and closed the
desk stand; as shown in Figure 16
Figure 16
Note:
If the power adapter is not plugged in, the icon
will display.
3.4.2 Sensor Operation Verification
The following steps verify proper operation of the sensors prior to installing the sensor array.
1. Verify proper operation of the rain gauge. Tip the sensor array back and forth several times.
You should hear a “clicking” sound within the rain gauge. Verify the rain reading on the dis-
play console is not reading 0.00. Each “click” represents 0.3mm of rainfall.
2. Verify proper operating of the wind speed. Rotate the wind cups manually or with a constant
speed fan. Verify the wind speed is not reading 0.0.
3. Verify proper operation of the indoor and outdoor temperature. Verify the indoor and out-
door temperature match closely with the console and sensor array in the same location
(About 3m apart). The sensors should be within 2°C (the accuracy is ±1°C). Allow about 30
minutes for both sensors to stabilize.
4. Verify proper operation of the indoor and outdoor humidity. Verify the indoor and outdoor
humidity match closely with the console and sensor array in the same location (about 3m