The doors can also be learned separately before connecting the sync cable. In case of astragal doors
and separate learning, the MASTER door must be held open before the SLAVE door learn is carried
out.
13.3
General adjustment
a Set the hold open time with the potentiometer on the control unit.
b Adjust the opening speed (OPSP) to comply with the applicable ANSI standard, A156.10 or
A156.19. Turning clockwise increases the speed (see Table I on page 79).
c Adjust the closing speed (CLSP) to comply with the applicable ANSI standard, A156.10 or
A156.19. Turning counter- clockwise decreases the speed (see Table I on page 79).
d Connect the required activation units.
e Check that the installation complies with AHJ (Authority Having Jurisdiction).
1009937-EI-1.0
Issue 2013-02-10
64
13 Start-up