12.3
Control units
12.3.1
CU-200
The CU-200 can be equipped with extension units, EXU-SI and/or EXU-SA, depending on the functions
required, see page 56 or 57.
1
2
3
4
5
6
PAG
MAT
SOS
AS1
AS2
AS3
AS4
1
O
N
2
3
4
5
6
7
OPD
LRN
GND
IIMP
XIMP
OPD
LOUT
+24V DC
SPTE OPSP
CLSP
CLTQ
POAS
HOT
LED
KHOT
8
AD
HOT / KHOT
5 s
1.5 s
30 s
CLSP
7 s
12 s
4 s
OPSP
5 s
12 s
2 s
PBO
LED
KICK
Encoder
Motor
Synchronizing of double doors
ON/OFF /HOLD open switch
Lock-out for OPD (–)
Overhead presence detection/Mat safety
Inner impulse controlled by
Inner impulse
(-) 0 VDC Ground
Overhead presence detection/Overhead
presence sensor (incl. 24 V, LOUT and Safety
Impulse)
Hold open time
DIP-switches shown in
OFF position
Closing torque
Power assist
Closing speed
Opening speed
Spring tension
PAG
MAT
SOS
AD
PUSH & GO
Safety mat*
Stop on stall
Activation Delay, 2s
External indicator
Key hold open time
Learn button
Panic breakout
**
**
(+) 24 VDC
***
After changing MAT dip switch a new LEARN must be carried out.
*
With heavier doors the time will increase.
**
Remove jumper if/when connecting the mechanical lock kick used for fire doors.
***
53
Issue 2013-02-10
1009937-EI-1.0
12 Electrical connection