PowerSwing US23-0922-02
22
© Copyright 2006 Besam Entrance Solutions. May not be reprinted or reproduced without permission.
Electrical Connection
Note!
During any work with the electrical connections the
main power
must be discon-
nected.
Control Units
The operator can be equipped with different control units adapted to the functions
required.
CSDA
This basic control unit is equipped with inputs for connection of automatic and
manual activation units such as radars, photocells, normal push buttons, emer-
gency push buttons etc. Electro -mechanical strike, slave control unit CSDA-S for
double doors as well as presence sensor IFD with limited functions can also be
connected.
CSDA-S
This slave control unit is used together with CSDA for double doors as explained
above.
EXA
This extension unit is mounted on top of the CSDA to extend the CSDA func-
tions with inputs for Push & Go, key impulse, presence impulse, inner and outer
impulse, off, exit, open and presence detection for both doors on a double door
application etc.
10-21-2002