background image

15

PowerSwing    US23-0922-02

© Copyright 2006 Besam Entrance Solutions. May not be reprinted or reproduced without permission. 

Mechanical Installation, PUSH

Operator with Arm System PUSH

Establish the Installation Height 

Establish the installation height X which is the distance from the underside of the 
wall to the underside of the mounting plate or adapter plate for jamb to jamb. Mark 
distance X on the wall. X can be between 2 – 87 mm (3/32” – 3-7/16”) depending 
on the shaft extension used; none, 20, 50 or 70.

Note: 2 mm (3/32”) achieves a fl ush unit when cover is mounted.

Mounting the Drive Unit (Mounting Plate Application)

1.  Stick the template to the wall aligned with the hinges and with the underside of 

the mounting plate aligned with the mark on the wall.

2.  Ensure that the template is perfectly horizontal. Punch and drill the four mount-

ing holes and the two holes for the door fi tting.

3.  Remove the template.
4.  Tap, plug or re in force with rivnuts and screw the drive unit tight.

Mounting the Door Fitting with Telescopic Part

1.  Remove the door fi tting from the arm system. 
2.  Screw the door fi tting to the door leaf tight.

Hinge center line

Drive shaft center line

10-21-2002

Summary of Contents for PowerSwing

Page 1: ...s with ANSI BHMA A156 10 standard for Power Operated Pedestrian Doors and A156 19 standard for Power Assist and Low Energy Power Operated Doors UL 325 Listed US23 0922 02 10 21 2002 Copyright 2006 Bes...

Page 2: ...vision all revised pages will get a new updated issue number year month day The first leaf pages 1 and 2 will always have the same issue num ber as the revised pages Changes will be marked with a vert...

Page 3: ...3 14 Operator with arm system PUSH 15 17 Operator with arm system PULL 18 21 Electrical connection 22 25 Control units 22 Connection of control units 23 25 Start Up 26 31 Connection of activation unit...

Page 4: ...811 US market FCC Part 15 which are designed to provide reasonable protection against such interference in a residential installation However there is no guarantee that interference will not occur in...

Page 5: ...werSwing works electro hydraulically It opens with an AC motor that via a hydraulic unit and an arm system transmits the power to the door leaf The closing power is from a coil spring The movement of...

Page 6: ...0 kg 220 lb for door leaf width 1400 mm 55 Higher door weights on request The PowerSwing complies with the door weights widths stated in the Controlled door closing EN 1154 sizes 3 6 Electrically powe...

Page 7: ...offered standard in an oversize length which is field cut to required length Optionally length L may be specified to the factory as part of order Pushing arm system shown PowerSwing 2 double door ope...

Page 8: ...ble holder 16 Adapter plate 17 Cover mounting clip C Center line drive shaft L1 C Center line hinge L2 Arm system PUSH P N 173 009 BK 173 883 Hybrid This arm systems is delivered with drive arm telesc...

Page 9: ...01 18 2001 9 PowerSwing US23 0922 02 Copyright 2006 Besam Entrance Solutions May not be reprinted or reproduced without permission Part Identification Options...

Page 10: ...PowerSwing US23 0922 02 10 Copyright 2006 Besam Entrance Solutions May not be reprinted or reproduced without permission Part Identification Options 10 21 2002...

Page 11: ...vnuts Tools required Torx T8 T10 T20 and T25 Metric hexagonal key 3 4 and 6 mm Flatblade screwdriver small Torque wrench with metric Allen socket 6 mm Installation on double doors If the operators are...

Page 12: ...e outside The diagram to the left shows a right handed outswing door Door Handing Architectural Hardware Industry You may occasionally see references to terms such as right hand reverse or left hand r...

Page 13: ...Establish the hinge center line C L1 3 Mark and drill the six holes 8 mm 5 16 for the fixing of the adapter plate to the jambs and header Countersink two holes as shown in the illustration so that th...

Page 14: ...direction of rotation before mounting the operator see page 17 1 Fix the adapter plate to the wall 2 Mount the cover mounting clips with end plates 3 Mount the operator Arm System PUSH Mount arm syst...

Page 15: ...none 20 50 or 70 Note 2 mm 3 32 achieves a flush unit when cover is mounted Mounting the Drive Unit Mounting Plate Application 1 Stick the template to the wall aligned with the hinges and with the un...

Page 16: ...lly with the operator shaft but especially with the drive arm so they are not damaged when the drive arm is tightened Tighten the screw to a torque of 25 Nm 19 lbf ft Adaptor Drive arm Adjusting the a...

Page 17: ...n door is in open position with a clearance of 2 mm 2 32 as shown below Fine adjust if necessary on limit switch and or on armsystem Note If door stop cannot be mounted on top of operator remove washe...

Page 18: ...anging the Direction of Rotation 1 Mount the washers and screws in the drive shaft one from each side 2 Dismantle the screws 4 pcs from the bearing sleeves on both sides 3 Fit the tools in the holes o...

Page 19: ...or 116 mm 1 13 16 2 19 32 3 3 4 or 4 9 16 depending on whether a shaft extension is used or not Mounting the Drive Unit Mounting Plate Application 1 Stick the template to the wall aligned with the hi...

Page 20: ...the door fitting to the door panel fastening securely 6 Mount the drive arm on the drive shaft with the door in unchanged position 90 Ensure that the teeth of the adaptor fit well with the operator dr...

Page 21: ...21 PowerSwing US23 0922 02 Copyright 2006 Besam Entrance Solutions May not be reprinted or reproduced without permission Mechanical Installation PULL P 10 21 2002...

Page 22: ...automatic and manual activation units such as radars photocells normal push buttons emer gency push buttons etc Electro mechanical strike slave control unit CSDA S for double doors as well as presenc...

Page 23: ...or reproduced without permission Electrical Connection Connection of Control Unit CSDA Single Doors Connect the main power to the main terminal block Note Accessories and activation units must not be...

Page 24: ...nection Connection of Control Units CSDA and CSDA S Double Doors For double door operators both operators have to be connected to the main power A four pole cable not enclosed has to be connected betw...

Page 25: ...he CSDA Snap on the EXA to the CSDA 1 The terminal TB1 4 on the basic control unit CSDA is changed to lock opening impulse in all program selector settings when the extension unit EXA is installed An...

Page 26: ...ation allows Turning clockwise decreases the speed b If a higher closing speed is required open the high speed closing valve HSC closed from factory Note If the installation requires adjustment of the...

Page 27: ...e pump pressure must be adjusted as follows 1 The factory set torque for PUSH is 70 Nm 52 lbf ft and for PULL 40 Nm 30 lbf ft at a door opening angle of 0 2 2 Measure the opening torque by using a spr...

Page 28: ...01 18 2001 PowerSwing US23 0922 02 28 Copyright 2006 Besam Entrance Solutions May not be reprinted or reproduced without permission Start Up Connection of Activation Units and Accessories...

Page 29: ...if the mat is active To obtain mat safety an optional limit switch is required Connect the limit switch to MI1 and set the function selectors FS 1 OFF FS 2 ON FS 3 ON and FS 4 OFF on the EXA Connecti...

Page 30: ...site side of the operator 4 Set the function selector FS 1 OFF on the EXA 5 Adjust if necessary the position of the switches Connection of Airing position to extension unit EXA Useful in private resid...

Page 31: ...31 PowerSwing US23 0922 02 Copyright 2006 Besam Entrance Solutions May not be reprinted or reproduced without permission Start Up Connection of PassPort Presence Sensor 10 21 2002...

Page 32: ...ishing plastic material Fitting and Removing the Cover Mount the end plates to the cover as shown below The cover is slid over flanges in the end plates and fixed to the underside of the mounting plat...

Page 33: ...tra 150 Swingmaster 350 450 MP series Power Swing as applicable The frame mounted fixed activators provided by the hard ware manufac turer aligning with the Tripper button at the upper latch mechanism...

Page 34: ...ining mounting holes install 10 24 bolts this assures proper alignment 8 Wire the Besam F50 Series Latch power supply detectors according to wiring diagram US23 0216 sheet 4 as applicable 9 Select the...

Page 35: ...ice to unlatch the door and restore automatic operation What is provided by Besam The fire door accessory package is a complete Underwriter s Laboratories UL and CUL listed package PowerSwing surface...

Page 36: ...m Entrance Solutions May not be reprinted or reproduced without permission Fire Door Installation Besam F 50 Series Latch Operator is surface applied mounted with push arm Latch panic wiring details u...

Page 37: ...tripper button and hold with tape if needed C Hold latch release against top mounting surface of frame and center latch release trigger in line with the rod with the tripper button just touching the...

Page 38: ...01 18 2001 PowerSwing US23 0922 02 38 Copyright 2006 Besam Entrance Solutions May not be reprinted or reproduced without permission Fire Door Installation Installation on fire doors...

Page 39: ...e Arm system has come loose Readjust pretension and tighten arm system Internal failure Replace operator The door does not open to the required angle Limit switch opening has come loose Check limit sw...

Page 40: ...ve 725 psi Factory set opening torque 13 Nm 9 6 lbf ft closing torque 10 Nm 7 4 lbf ft Oil fill screw Magnetic valve with ball and spring Leaky valve will cause creeping close at 90 Sticking valve wil...

Page 41: ...hout permission Installation Examples Aluminium profile system Plasterboard wall Reinforced concrete wall and brick wall Plasterboard wall einforced concrete wall A Steel reinforcement or rivnut B Ste...

Page 42: ...01 18 2001 PowerSwing US23 0922 02 42 Copyright 2006 Besam Entrance Solutions May not be reprinted or reproduced without permission...

Page 43: ...01 18 2001 43 PowerSwing US23 0922 02 Copyright 2006 Besam Entrance Solutions May not be reprinted or reproduced without permission...

Page 44: ...Copyright 2006 Besam Entrance Solutions May not be reprinted or reproduced without permission...

Reviews: