15
PowerSwing US23-0922-02
© Copyright 2006 Besam Entrance Solutions. May not be reprinted or reproduced without permission.
Mechanical Installation, PUSH
Operator with Arm System PUSH
Establish the Installation Height
Establish the installation height X which is the distance from the underside of the
wall to the underside of the mounting plate or adapter plate for jamb to jamb. Mark
distance X on the wall. X can be between 2 – 87 mm (3/32” – 3-7/16”) depending
on the shaft extension used; none, 20, 50 or 70.
Note: 2 mm (3/32”) achieves a fl ush unit when cover is mounted.
Mounting the Drive Unit (Mounting Plate Application)
1. Stick the template to the wall aligned with the hinges and with the underside of
the mounting plate aligned with the mark on the wall.
2. Ensure that the template is perfectly horizontal. Punch and drill the four mount-
ing holes and the two holes for the door fi tting.
3. Remove the template.
4. Tap, plug or re in force with rivnuts and screw the drive unit tight.
Mounting the Door Fitting with Telescopic Part
1. Remove the door fi tting from the arm system.
2. Screw the door fi tting to the door leaf tight.
Hinge center line
Drive shaft center line
10-21-2002