Besam Entrance Solutions
18
1/31/2008
(1) Back Check Switch
(2) Bottom Cam
(3) Break Out Switch
(4) Latch Switch
(5) Top Cam
(6) Home Switch
48B
Adjustment of built-in mechanical full open door stops
The built-in mechanical full open stops are factory set to 90 degrees. If needed, the full open stops
can be adjusted as shown below.
79B
(A) Left Hand Overhead Concealed
Remove the square end cap (1) to access the LH adjustment screw. Turn the screw out to decrease
the opening angle, in to increase. Reinstall square cap.
80B
(B) Left Hand Surfaced Applied
Loosen set screw (2).
Adjust end cap screw (3) for opening angle Screw out to increase, and in to decrease. If additional
adjustment is needed, remove the end cap and adjust the internal screw as per step “A”. Replace end
cap.
81B
(C) Right Hand Overhead Concealed and Surfaced Applied
Loosen door stop lock nut (4)
Adjust bolt (5) for opening angle. Screw out to increase, and in to decrease.